Hellenbrand TNT Series manual Mechanical or Electronic Meter/Turbine Options

Page 3

TN2 Standard System Design Options

(for more specific information on the various system designs, contact your local Hellenbrand representative or go to: www.hellenbrand.com

1.

Single Tank Systems - XT Controller

3. Twin, Tri-Plex & Four-Plex Demand Recall Progressive

 

• Time Clock

Systems - 3214NXT Controller

2.

• XT Controller Electronic Meter Demand

2-4 Units

Twin, Tri-Plex & Four-Plex Systems - 3200NXT Controller

• Individual Meters

 

Parallel Operation

• Single or Individual Brine Systems

 

2-4 Units

 

 

• Individual Meters

 

• Single or Individual Brine Systems

Alternating Operation

2-4 Units

• Twin Systems - One Meter or Two Meters

Tri-Plex & Four-Plex Systems - Individual Meters

• Single or Individual Brine Systems

3200NXT Electronic Controller

The 3200NXT Network Controller uses on-board communica- tions capabilities to link multiple valves (via off-the shelf CAT3, CAT5, or better cables) for a variety of multiple system types as described above.

Program Features:

2x16 character backlit LCD display

Networks up to four units

Auxiliary inputs and outputs

-Remote signal start input

-Remote lockout input

-Programmable relay output/chemical pump output

Easy installation with plug-in wiring harnesses

Front panel diagnostics button

-Flow rate

-Peak flow rate

-Totalizer

-Hours between last two regenerations.

-Hours since last regeneration

-Adjustable volume remaining

-Valve position

Three programming levels

User mode

Master programming

Diagnostics mode

Note: The 3214NXT Demand Flow Network Controller is used for demand recall applications.

3214NXT Demand Flow Network Controller

The 3214NXT Demand Flow Network Controller can be pro- grammed to bring multiple units to the service position and back to standby based on system demand flow. The 3214NXZT De- mand Flow Network Controller used on-board communication capabilities to link multiple valves via standard CAT3, CAT5, or better communication cables.

Program Features:

Network two to four valves

Simple, on-site network programming

Easy installation with plug-in wiring harnesses

Shift key allows digit selecting in programming

2x16 character LCD backlit display (letter or digit codes not needed)

Valve, piston, and cam type default storage

• User and master programming modes

• Diagnostic mode:

- Current flow rate

- Peak flow rate (can be reset) - Totalizer (can be reset)

- Hours between last two regenerations - Hours since last regeneration

- Volume remaining (adjustable) - Valve addresses

Three programming levels

User mode

Master programming

Diagnostics mode

Mechanical or Electronic Meter/Turbine Options:

Size

Flow Ranges

Accuracy

1.5” CC Meter

0.5

– 60 GPM

+5%

2” CC Meter

1.5

- 150 GPM

+5%

Image 3
Contents TNT Series TNT Series Control Valve -Three Inch Inlet/Outlet Hellenbrand Means Quality and ReliabilityMechanical or Electronic Meter/Turbine Options Typical Single Tank Installation Twin Alternating Tank InstallationTNT Series SideMount TNT Service Rates & Pressure Drop Charts Commercial/Industrial Tanks Pressure Drop ChartsTNT Physical Specifications TNT Series Fiberglass DimensionsTNT Capacity Ratings

TNT Series specifications

The Hellenbrand TNT Series represents a significant advancement in water treatment technology, specifically designed to offer high-performance solutions for residential and commercial applications. Known for its innovative design and robust performance, the TNT Series combines advanced filtration techniques with user-friendly operation, catering to diverse water quality challenges.

One of the standout features of the TNT Series is its multi-stage filtration system. This system employs multiple processes to effectively remove impurities, contaminants, and undesirable minerals from water. Each stage is engineered to target specific types of pollutants, ensuring that the water meets strict quality standards. The result is crystal-clear water free from sediment, chlorine, heavy metals, and other harmful substances that can affect health and taste.

Another key characteristic of the TNT Series is its use of advanced technology for efficiency and ease of maintenance. The series includes smart control systems that allow users to monitor and manage water quality in real-time. These smart systems come equipped with diagnostic tools, providing alerts for necessary maintenance or component replacement, thus prolonging the system’s lifespan and ensuring optimal performance.

Energy efficiency is a priority in the design of the Hellenbrand TNT Series. The units are engineered to operate with minimal energy consumption, reducing overall utility costs for homeowners and businesses. Additionally, the design features a compact footprint, making it easy to install in various spaces without requiring significant modifications to existing plumbing systems.

The TNT Series also incorporates user-friendly features, such as a simple interface for adjusting settings and monitoring performance. This focus on usability ensures that even individuals without technical expertise can operate and maintain the system with ease.

Durability and reliability are hallmarks of the TNT Series. Constructed from high-quality materials, these systems are built to withstand the rigors of continuous use while maintaining optimal filtration effectiveness. Hellenbrand's commitment to quality ensures that customers receive long-lasting products that deliver consistent results.

In summary, the Hellenbrand TNT Series stands out in the market for its comprehensive filtration, advanced technology, energy efficiency, ease of use, and durability. This series is an excellent choice for those seeking reliable and effective water treatment solutions, making it a valuable investment for both residential and commercial installations. With the Hellenbrand TNT Series, users can enjoy peace of mind knowing their water quality is in expert hands.