Kenmore 625.38376, 625.39376 warranty Faceplate Timer Features

Page 22

Faceplate Timer Features

EXTRA RECHARGE

Sometimes, a manually started regeneration (recharge) may be desired, or needed. Two examples are:

You have used more water than usual (guests visiting) and you may run out of soft water before the next timer started regeneration.

You did not refill the softener with salt before it was gone. Add salt to the softener before regenerating.

You can start a regeneration right away, or you can set the timer to regenerate at the next 2:00 AM (or other pre- set recharge time).

RECHARGE NOW

Press the REGENERATION button and hold until *RECHARGE, Serv and Fill begin to flash in the display. Upon reaching fill, the first cycle of regeneration, the flashing Serv goes off and Fill is on steady. RECHARGE continues to flash. This regeneration will last for about 2 hours. After the 2 hours, you will have soft water again.

*NOTE: If the CLEAN feature is set to ON, a cleaning backwash (CLEAN and Bkwsh or Rinse flashes in the display, along with the minutes of the clean cycle remaining) precedes the recharge.

RECHARGE TONIGHT

Press and release (do not hold) the REGENERATION button. RECHARGE TONIGHT flashes in the display, and the softener begins regeneration at the next preset recharge time. Press and release the REGENERATION button once more if you decide to cancel the regenera-

Brinewell

Salt Level

SALT SIGNAL

LEVEL LEVEL

PM

8

7RECHARGE NOW

6

5

4

3

2

1

SALT SIGNAL

LEVEL LEVEL

PM

8

7RECHARGE TONIGHT

6

5

4

3

2

1

Indicator Light

Bars,

Salt Level

SALT

LEVEL

Decal

FIG. 33

FIG. 34

SALT SIGNAL

LEVEL LEVEL

8

7

6

5

4

3

2 ￿

1 ￿

tion, and RECHARGE TONIGHT will not flash in the dis- play.

FIG. 35

SALT MONITOR SYSTEM

The face plate timer has a low salt monitor with an indi- cator light to remind you to add salt to the storage tank.

To set this monitor system:

1.Lift the salt hole cover and level the salt in the storage tank.

2.The salt level decal, on the brinewell inside the tank, has numbers from 0 to 8 (see drawing below). Observe the number the leveled salt is at or closest to.

3.Now, press the RESET SALT LEVEL button until black bars display up to the salt level number. For example, the figure shows the salt level at 6.

4.Finally, set the level you want the low salt indicator light to come on. Press the SET LOW SALT LIGHT button until a (*) shows opposite this number. In the example, the light will come on when the stored salt drops to level 2. At level 2, the storage tank is about 1/3 full. This is the lowest you should allow the stored salt level to drop to.

5.If you wish to turn the salt monitor off, press the SET LOW SALT LIGHT button until OFF shows above.

NOTE: Your salt monitor is an estimate of your salt level; accuracy depends on the type of salt used and other regeneration characteristics.

ADDING SALT TO STORAGE TANK

The Salt Monitor System will turn the low salt light on to warn you when to refill with salt. Check for a low salt light a few weeks after you install the softener, and every week after that. Add salt at about the #2 salt monitor level. At this level, the tank is about 1/3 full. Never let the softener use all the salt before refilling. Without salt, you will soon have hard water. After filling, reset the Salt Monitor System.

Note: You will have a loss in softening capacity and may get partly hard water if less than 10 inches (salt monitor level 2) of salt is in the storage tank.

Questions? Call The Kenmore Water Line 1-800-426-9345

22

Image 22
Contents Repair or Parts ? Call toll free Save this ManualTEN Year Limited Warranty Against Leaks ONE Year Limited Warranty on Water SoftenerThree Year Limited Warranty on Electronic Parts Disclaimer of implied warranties limitation of remediesTable of Contents Facts and Figures to KeepSafety Guides Small Parts Unpack and Check Your CartonParts Descriptions Inspect ShipmentPlan Your Installation Plan Your InstallationProper Order to Install Water Treating Equipment Tools NeededWhere to Install the Water Softener Soft, HotSuggested Slab Foundation Installation Draw in Your Pipes and FittingsOUT PIPE, FITTINGS, Other Materials NeededBefore Installing Checks & Tests Read Before Beginning InstallationAssemble Drain Port Elbow Bypass Valve Install Plastic Bypass ValveAssemble Inlet Outlet ADAPTORS, or Plastic Bypass Valve Inlet and Outlet Threaded AdaptorsInstalling 3 Valve Bypass and Pipes Install 3-Valve BypassInstalling Holding Clips Valve BypassTypical Soldering Connections Locate Water Softener and Connect PipesMove Softener Into Place Position Softener Into PlaceConnect the Valve Drain Hose Connect Valve and Salt Tank DrainsConnect Salt Tank Overflow Tubing Single Bypass Leak TestHouse Main Water Shutoff Valves Leak TestElectrical Requirements Water Meter Jumper WireConnecting Transformer Cold Water Pipe GroundingInstall Covers Install Covers and Restart Water HeaterProgram The Timer Program the TimerSET Water Hardness Number SET Present Time of DAYSET Regeneration Time Sanitize the Water Softener Sanitize The Water SoftenerSanitize Your Water Softener AS Follows Adding Salt to the Storage Tank Adding Salt To The Storage TankWater Softening Salt with Iron Removing Additives Check List of STEP-BY-STEP Guides to Install Check ListFaceplate Timer Features Gallons / Liters Maximum Days Between Regenerations Gallon or Liter readings Water usage and flow dis Tank LightMaximum days between regenerstions The face KENMORE’S Ultra Cleansing Feature Recharge Time Remaining and Valve Position IndicatorsError Code Program MemoryHow Your Water Softener Works Water Flow Through Softener in ServiceSoft Water Service and Regeneration Water Flow Through Softener in FillWater Flow Through Softener Brining and Brine Rinse Water Flow Through Softener in BackwashAutomatic Bypass Water Flow Through Softener Fast RinseElectronics Salt Bridge Care Of Your Water SoftenerSalt Bridge Iron from Resin BED Keeping the Water Softener CleanNozzle & Venturi Drain ALL Water from Softener Protect the Water Softener from FreezingProblem Cause Correction Checklist to Help YOU Save MoneyBypass Valves SpecificationsModel 383760 Timer Code H Model 393760 Timer Code H InchesOther Specifications Faceplate Service Tech InformationWiring Schematic Always Make These Initial Checks FirstManual Initiated Electronics Diagnostics Procedure for Removing Error Code from FaceplatePossible Defect Code Troubleshooting Valve Position Indicators Timer PWA ReplacementManual Advance Regeneration Check Brine Valve Float SettingCycle Flow Rates Gallons PER MIN Assembly Rotary Valve ServiceDisassembly To Relieve PressureFill Cycle Water Flow Through the Softener Valve Service CycleBrining and Brine Rinse Cycle Backwash Cycle Water Flow Through the Softener Valve Backwash CycleFast Rinse Cycle Fast Rinse CycleExploded View Water Softener Complete Parts ListPart Number Part Description Inlet Outlet Grounding Clamps Brine Valve Assembly Wear-Strip Seal Cross-Section View Key Part Number Part Description Get it fixed, at your home or ours
Related manuals
Manual 48 pages 29.92 Kb Manual 48 pages 54.31 Kb

625.39376, 625.38376 specifications

The Kenmore 625.38376 is a versatile and efficient air purifier designed to enhance indoor air quality in various environments, including homes, offices, and other spaces. This model is particularly recognized for its impressive filtration capabilities and user-friendly features, making it a popular choice among consumers seeking cleaner air.

One of the standout features of the Kenmore 625.38376 is its advanced three-stage filtration system. This system includes a pre-filter, a true HEPA filter, and an activated carbon filter. The pre-filter captures larger particles such as dust and pet hair, which helps to extend the life of the HEPA filter. The true HEPA filter is capable of trapping 99.97% of particles as small as 0.3 microns, effectively removing allergens like pollen, smoke, and mold spores from the air. The activated carbon filter further enhances the unit's performance by absorbing odors and volatile organic compounds (VOCs), contributing to a fresher indoor environment.

In addition to its powerful filtration system, the Kenmore 625.38376 includes several user-friendly technologies and features. The air purifier is equipped with a smart air quality sensor that continuously monitors the air quality in real-time. This sensor automatically adjusts the fan speed based on the pollution levels detected, ensuring optimal cleaning performance without unnecessary energy consumption. Users can easily track air quality levels through an intuitive digital display that shows the current status.

Another significant characteristic of the Kenmore 625.38376 is its quiet operation. The unit is designed to operate at low noise levels, making it suitable for use in bedrooms and other quiet spaces. It features multiple fan speeds, allowing users to adjust the airflow according to their specific preferences and needs.

The Kenmore 625.38376 is also energy efficient, certified by ENERGY STAR. This certification assures consumers that the unit meets stringent energy efficiency guidelines, promoting lower electricity bills and a reduced environmental impact.

In summary, the Kenmore 625.38376 air purifier combines advanced filtration technologies, smart sensors, quiet operation, and energy efficiency to create a reliable solution for improved indoor air quality. Its thoughtful design and effective performance make it an excellent choice for individuals looking to breathe cleaner air in their homes.