Kenmore 625.38376, 625.39376 warranty Problem Cause Correction, Checklist to Help YOU Save Money

Page 32

Care Of Your Water Softener

CHECKLIST TO HELP YOU SAVE MONEY

If your water softener fails to work, make the following easy checks. Often, you will find what is wrong yourself and you won’t have to call and wait for service. If you do not find anything wrong, while making the checks, and your sof- tener still does not work, call your Sears Service Department.

1.Also read ERROR CODE.

2.If an error code is not displayed, press and hold the SELECT1 button until the display changes. Then, press the SELECT1 button again and hold until a flashing code appears. It must show H 32 for Model 38376 or H 33 for Model 39376. If any other number shows, the face plate computer is working on incorrect input and would proba- bly be the cause of the problem. To set the correct code, press either the UP or DOWN button. When correct model code shows, press SELECT1 to return a flashing 12:00 AM display. Reset the present time, hardness num- ber, etc.

PROBLEM

CAUSE

CORRECTION

 

 

 

No soft water

No salt (or salt bridged) in the storage tank

Add salt, see page 20, or break the salt bridge,

 

 

see page 29. Press REGENERATION button

 

 

and hold to start a regeneration, see page 22.

 

 

 

 

Transformer unplugged at the wall outlet, or

Check for loss of power due to any of these

 

power cable leads loose from the electronic

and correct. With the power back on, look at

 

board, fuse blown, circuit breaker popped, or

the time display and read PROGRAM MEMO-

 

circuit switched off.

RY, see page 25.

 

 

 

 

Manual bypass valve(s) in bypass position

Look at Fig. 18 & 19 on page 15. Move the

 

 

stem in a single valve to service. In a 3-valve

 

 

bypass, open the inlet and outlet valve, and be

 

 

sure to fully close the bypass valve.

 

 

 

 

Dirty, plugged or damaged nozzle venturi

Take apart and clean or replace damaged

 

 

parts, see page 30.

 

 

 

 

Valve drain hose plugged ir restricted

The drain hose must not have kinks, sharp

 

 

bends, or be raised too high above the soften-

 

 

er, see page 14.

 

 

 

Water hard sometimes

Hardness number setting too low

Press and release the SELECT button until

 

 

HARDNESS shows in the display. Read the

 

 

hardness number in the display and be sure

 

 

the same grains per gallon number is shown

 

 

as on your water analysis report. See page 19

 

 

to reset. Press and release the SELECT button

 

 

uuntil the present time shows in the display.

 

 

 

 

Using hot water when softener is regenerat-

Avoid using hot water during this time because

 

ing

the water heater refills with hard water, see

 

 

Automatic Bypass, page 28.

 

 

 

 

Increase in the grains of hardness in your

Ask your Sears retail store for a new water

 

water supply

analysis. Then make a new hardness number

 

 

setting, page 18.

 

 

 

Brine tank flooded

Restricted drain line

Check for kinks, bends or obstructions, see

 

 

page 14.

 

 

 

 

Plugged or dirty nozzle & venturi

Take apart and clean or replace damaged

 

 

parts, see page 30.

 

 

 

 

Valve rotor-disc & seals

Check for scratches or grooves, replace if

 

 

needed.

 

 

 

Salty tasting water

Restricted drain line

Check for kinks, bends or obstructions, see

immediately after

 

page 14.

regeneration

 

 

Questions? Call The Kenmore Water Line 1-800-426-9345

32

Image 32
Contents Repair or Parts ? Call toll free Save this ManualONE Year Limited Warranty on Water Softener Three Year Limited Warranty on Electronic PartsTEN Year Limited Warranty Against Leaks Disclaimer of implied warranties limitation of remediesTable of Contents Facts and Figures to KeepSafety Guides Unpack and Check Your Carton Parts DescriptionsSmall Parts Inspect ShipmentPlan Your Installation Proper Order to Install Water Treating EquipmentPlan Your Installation Tools NeededWhere to Install the Water Softener Soft, HotSuggested Slab Foundation Installation Draw in Your Pipes and FittingsOUT PIPE, FITTINGS, Other Materials NeededAssemble Drain Port Elbow Read Before Beginning InstallationBefore Installing Checks & Tests Install Plastic Bypass Valve Assemble Inlet Outlet ADAPTORS, or Plastic Bypass ValveBypass Valve Inlet and Outlet Threaded AdaptorsInstall 3-Valve Bypass Installing Holding ClipsInstalling 3 Valve Bypass and Pipes Valve BypassLocate Water Softener and Connect Pipes Move Softener Into PlaceTypical Soldering Connections Position Softener Into PlaceConnect Salt Tank Overflow Tubing Connect Valve and Salt Tank DrainsConnect the Valve Drain Hose Leak Test House Main Water Shutoff ValvesSingle Bypass Leak TestWater Meter Jumper Wire Connecting TransformerElectrical Requirements Cold Water Pipe GroundingInstall Covers and Restart Water Heater Program The TimerInstall Covers Program the TimerSET Regeneration Time SET Present Time of DAYSET Water Hardness Number Sanitize Your Water Softener AS Follows Sanitize The Water SoftenerSanitize the Water Softener Water Softening Salt with Iron Removing Additives Adding Salt To The Storage TankAdding Salt to the Storage Tank Check List of STEP-BY-STEP Guides to Install Check ListFaceplate Timer Features Gallons / Liters Maximum Days Between Regenerations Maximum days between regenerstions The face Tank LightGallon or Liter readings Water usage and flow dis Recharge Time Remaining and Valve Position Indicators Error CodeKENMORE’S Ultra Cleansing Feature Program MemoryWater Flow Through Softener in Service Soft Water Service and RegenerationHow Your Water Softener Works Water Flow Through Softener in FillWater Flow Through Softener Brining and Brine Rinse Water Flow Through Softener in BackwashElectronics Water Flow Through Softener Fast RinseAutomatic Bypass Salt Bridge Care Of Your Water SoftenerSalt Bridge Nozzle & Venturi Keeping the Water Softener CleanIron from Resin BED Drain ALL Water from Softener Protect the Water Softener from FreezingProblem Cause Correction Checklist to Help YOU Save MoneySpecifications Model 383760 Timer Code H Model 393760 Timer Code HBypass Valves InchesOther Specifications Service Tech Information Wiring SchematicFaceplate Always Make These Initial Checks FirstPossible Defect Code Procedure for Removing Error Code from FaceplateManual Initiated Electronics Diagnostics Troubleshooting Valve Position Indicators Timer PWA ReplacementCycle Flow Rates Gallons PER MIN Brine Valve Float SettingManual Advance Regeneration Check Rotary Valve Service DisassemblyAssembly To Relieve PressureBrining and Brine Rinse Cycle Water Flow Through the Softener Valve Service CycleFill Cycle Water Flow Through the Softener Valve Backwash Cycle Fast Rinse CycleBackwash Cycle Fast Rinse CycleExploded View Part Number Part Description Parts ListWater Softener Complete Inlet Outlet Grounding Clamps Brine Valve Assembly Wear-Strip Seal Cross-Section View Key Part Number Part Description Get it fixed, at your home or ours
Related manuals
Manual 48 pages 29.92 Kb Manual 48 pages 54.31 Kb

625.39376, 625.38376 specifications

The Kenmore 625.38376 is a versatile and efficient air purifier designed to enhance indoor air quality in various environments, including homes, offices, and other spaces. This model is particularly recognized for its impressive filtration capabilities and user-friendly features, making it a popular choice among consumers seeking cleaner air.

One of the standout features of the Kenmore 625.38376 is its advanced three-stage filtration system. This system includes a pre-filter, a true HEPA filter, and an activated carbon filter. The pre-filter captures larger particles such as dust and pet hair, which helps to extend the life of the HEPA filter. The true HEPA filter is capable of trapping 99.97% of particles as small as 0.3 microns, effectively removing allergens like pollen, smoke, and mold spores from the air. The activated carbon filter further enhances the unit's performance by absorbing odors and volatile organic compounds (VOCs), contributing to a fresher indoor environment.

In addition to its powerful filtration system, the Kenmore 625.38376 includes several user-friendly technologies and features. The air purifier is equipped with a smart air quality sensor that continuously monitors the air quality in real-time. This sensor automatically adjusts the fan speed based on the pollution levels detected, ensuring optimal cleaning performance without unnecessary energy consumption. Users can easily track air quality levels through an intuitive digital display that shows the current status.

Another significant characteristic of the Kenmore 625.38376 is its quiet operation. The unit is designed to operate at low noise levels, making it suitable for use in bedrooms and other quiet spaces. It features multiple fan speeds, allowing users to adjust the airflow according to their specific preferences and needs.

The Kenmore 625.38376 is also energy efficient, certified by ENERGY STAR. This certification assures consumers that the unit meets stringent energy efficiency guidelines, promoting lower electricity bills and a reduced environmental impact.

In summary, the Kenmore 625.38376 air purifier combines advanced filtration technologies, smart sensors, quiet operation, and energy efficiency to create a reliable solution for improved indoor air quality. Its thoughtful design and effective performance make it an excellent choice for individuals looking to breathe cleaner air in their homes.