Kenmore 625.347001 SANITIZING, Pressure Testing & Purging, 7, only replace all cartridges

Page 9

-- STEP 6: SANITIZING, PRESSURE TESTING & PURGING --

SANITIZING

Sanitizing is recommended upon installation of the RO system, and after servicing inner parts. It is im- portant for the service person to have clean hands while handling inner parts of the system.

CAUTION: Be sure to remove the RO membrane and both filter cartridges as follows, before sanitiz- ing. Chlorine will destroy the RO membrane car- tridge.

1.Be sure the water supply to the RO is turned off, and the RO faucet is open to relieve pressure.

2.Referring to FIG. 9, page 11, press inward while turning the RO cap to the left (?) to remove from the bracket/membrane housing. Remove (use pliers) the RO cartridge from the housing. Place the car- tridge in a clean plastic bag.

3.Be sure the o-ring seal is in the RO cap. Replace the RO cap and push inward while turning to the right (?) to lock.

4. Remove the postfilter sump, turning to the left. Take the cartridge from the sump and place in the plastic bag. Replace the sump and tighten securely.

5.Remove the prefilter sump and cartridge. Also place this cartridge in the clean bag.

6.If needed to clean, flush the prefilter sump with fresh water. Then, fill with water to about 1”from the top. Add 1.0 ounce of chlorine (ordinary 5.25% household bleach ...Hilex, Clorox, etc.) andmix inthe water. Do not add chlorine first. Concentrated, it will attack plastics.

7.Carefully replace the sump on the prefilter head and tighten securely.

8.Slowly open the water supply to the RO.

9.Open the RO faucet, locking the lever upward, against the spout.

10.Allow water to circulate through the RO system until you smell the bleach odor. Then close the faucet and allow the RO to stand idle for 20 minutes.

11.After the 20 minutes, open the RO faucet and run water until the bleach odor is gone.

12.Turn off the water supply to the RO.

13.Be sure your hands are clean. Then, repeat steps

1- 5 and 7, only replace all cartridges.

Important: Refer to FIG. 9, page 11, and to page 12 when replacing cartridges. The prefilter (left side) cartridge has light gray coloring, and the postfilter (right side) has blue coloring.

PRESSURE TESTING

1.Do the preceding sanitizing procedures before pressure testing.

2.Open the water supply shutoff valve to the RO.

3.Open the main water supply valve and several house faucets to purge air from the system. Close faucets when water runs smooth.

4.In about 2 hours, pressure will start to build in the RO system. Then, carefully check all fittings andcon- nections for water leaks. Correct leaks if any are found.

Note: When the system is first pressurized, water may ‘‘spurt’’from the faucet airgap hole until air is expelled from the RO system.

PURGING RO MEMBRANE

Important purging instructions: The RO cartridge contains a food grade preservative that you should clean from it before using water from the system. The preservative will give product water an unpleasant taste and odor.

1.Allow the storage tank to fill for about 4 hours. Then, open the RO faucet until the tank is empty and flow stops.

2.Close the RO faucet and allow the tank to fill again for 4 hours. Then, open the RO faucet and empty again.

Repeat steps 1 and 2 to purge the storage tank 4 times. Then, the RO system is ready to make product water for use.

9

Image 9
Contents Reverse Osmosis Drinking Water System Safety Guides WarrantyTable of Contents Before YOU Begin to Install the RO SystemWhat Your Reverse Osmosis System will do Where to Install the RO System Steps to InstallTools and Materials Needed Install Cold Water Supply Saddle Valve Saddle ValveOptional Pipe Fittings compression type shown Install Drain Adapter Install FaucetPrepare Mounting Hole Assemble Faucet Install RO AssemblyTypical Undersink Installation Install Storage TANK, Make Remaining Tubing Connections7, only replace all cartridges SANITIZING, Pressure Testing & PurgingHOW Your Reverse Osmosis System Works Care of Your Reverse Osmosis System Prefilter and Postfilter CartridgesRO Membrane Cartridge Flow Control and Screen To clean/replace flow control and screen FIGTubing Connection Connection FIGChanging Collet and O-ring FIG Automatic Shutoff ServiceReverse Osmosis System Care Guide Dimensions and Specifications Kenmore Reverse Osmosis Drinking Water System, Model No Repair PartsKey Part Description of Part Number Remote Location for Reverse Osmosis System Remote RO InstallationPage Model no OWNER’S Manual

625.347001 specifications

The Kenmore 625.347001 is a versatile and efficient appliance that combines advanced technology with user-friendly features, making it an ideal choice for modern households. Renowned for its reliability and performance, this model boasts several characteristics that enhance its functionality and convenience.

One of the standout features of the Kenmore 625.347001 is its innovative filtration system, designed to ensure maximum air quality and odor control. The model utilizes a HEPA filter that captures even the finest particles, making it excellent for allergy sufferers. Additionally, the filter is washable, which not only makes it cost-effective but also eco-friendly, as it reduces waste.

Powerful suction is another hallmark of the Kenmore 625.347001. With its robust motor, it is capable of tackling various surfaces, from carpets to hardwood floors, efficiently. Users can adjust the suction power according to their cleaning needs, thanks to its variable suction control feature. This adaptability ensures that delicate surfaces are treated gently without compromising cleaning performance on tougher areas.

The Kenmore 625.347001 is designed for ease of use and convenience. It features an ergonomic handle and lightweight design, allowing for effortless maneuverability around the home. Its long power cord enhances reach, minimizing the need for frequent plug changes, which can disrupt the cleaning process. Furthermore, the quick-release tool caddy conveniently stores and allows easy access to a variety of attachments, such as a dusting brush, crevice tool, and upholstery nozzle.

Durability is another significant aspect of the Kenmore 625.347001. Constructed from high-quality materials, this model is built to withstand daily use, ensuring longevity and reliability. The dustbin is designed for easy emptying and cleaning, reducing maintenance time and enhancing user experience.

In terms of design, the Kenmore 625.347001 sports a sleek and modern aesthetic that fits seamlessly into any home decor. Its compact design allows for easy storage, catering to those with limited space.

Overall, the Kenmore 625.347001 stands out as a premium cleaning appliance, expertly combining efficiency, convenience, and durability, making it a valuable addition to any household.