Amtrol WELL-X-TROL, WELL-X1 warranty Table of Contents, General Safety Information

Page 2

1. TABLE OF CONTENTS

 

GENERAL SAFETY INFORMATION

2

COMPONENTS

3

INSTALLATION AND SIZING CONSIDERATIONS

4

INSTALLATION CONSIDERATIONS

5

PLUMBING

6

WIRING

8

STARTUP & ADJUSTMENT

9

PUMP PROTECTION & DIAGNOSTICS

13

TROUBLESHOOTING

14

REPLACEMENT PARTS

15

2. GENERAL SAFETY INFORMATION

 

This Product, like most Products under pressure, may over time corrode. weaken and burst or explode, causing serious or fatal injury, leaking or flooding and/or property damage. To minimize risk, a licensed professional must install and periodically inspect and service the Product. A drip pan connected to an adequate drain must be installed if leaking or flooding could cause property damage. Do not locate in an area where leakage of the tank or connections could cause property damage to the area adjacent to the appliance or to lower floors of the structure.

Chlorine & Aggressive Water: The water

quality can significantly influence the life of this Product. You should test for corrosive elements, acidity, total solids and other relevant contaminants, including chlorine and treat your water appropriately to insure satisfactory performance and prevent premature failure.

NOTE: Inspect for shipping damage and notify freight carrier or store where purchased immediately if damage is present. To avoid risk of personal injury and property damage, if the product appears to be malfunctioning or shows signs of corrosion, call a qualified professional immediately. Current copies of the Product manual can be viewed at www.amtrol.com. Use proper safety equipment when installing.

ELECTROCUTION AND EXPLOSION HAZARD! Before

work is performed on the Product, turn off the power to the Product and release all pressure in the system.

As in all plumbing products and water storage vessels, bacteria can grow in this Product, especially during times of non-use. Consult your local plumbing professional regarding any steps you may wish to take to safely disinfect your home’s plumbing system.

DANGER! EXPLOSION HAZARD, WHEN THE WELL-X1HAS BEEN IN SERVICE AND A CHANGE TO A HIGHER PRE-CHARGE PRESSURE IS NECESSARY DUE TO A REQUIRED CHANGE IN THE PRESSURE SWITCH SETTING, FAILURE TO FOLLOW INSTRUCTION MANUAL CAN CAUSE A RUPTURE OR EXPLOSION, POSSIBLY CAUSING SERIOUS OR FATAL INJURY, AND/OR PROPERTY DAMAGE. • DO NOT ADJUST THE PRE-CHARGE PRESSURE IF THERE HAS BEEN A REDUCTION OF THE PUMP CYCLE TIME OR THE PRE-CHARGE PRESSURE COMPARED TO ITS INITIAL SETTING. THIS IS BECAUSE REDUCTION IN

PUMP CYCLE TIME CAN RESULT FROM LOSS OF TANK AIR PRESSURE WHICH IN TURN CAN MEAN THERE MAY BE INTERNAL CORROSION AND ANY RE-PRESSURIZATION OR ADDITIONAL PRESSURE COULD RESULT IN RUPTURE OR EXPLOSION, AND/OR PROPERTY DAMAGE.

RELIEF VALVE REQUIRED. A relief valve

has been installed which is set to open at excessive pressures (100 psig or more). This will protect the Well-X1and other system components should the pressure switch malfunction and fail to shut the pump off. The relief valve is installed at the connection of the Well-X1to the system piping.

Before attempting any service and

disassembly, shut off power to the pump. Ensure power is disconnected prior to removing motor. Ensure power is disconnected before cleaning is attempted.

This control is capable of running pumps to pressures that may exceed the limitations of system components. Never set the operation pressure higher than that of the safe system capacity.

This control can be adjusted to a narrow pressure differential. This can cause the pump to cycle rapidly with an improperly sized tank, leading to pump damage. This may require a larger pressure tank than normally used.

CALIFORNIA PROPOSITION 65 WARNING:

This product contains a chemical known by the State of California to cause cancer and to cause birth defects or other reproductive harm. (California Installer/Contractor - California law requires that this notice be given to consumer/

end user of this product.) For more information: www. amtrol.com/prop65/htm

Every Well-X1is air tested to 125 psig, the maximum working pressure for the Well-X1.

The pump controller is not a disconnect. The pump may be activated at any time. The electrical system must be considered energized at all times unless the circuit breaker is open. The disconnect for the controller must break all incoming power lines. As with a mechanical pressure switch, when installed with three wire 230 vac pumps or any 3-phase pump, a standard pump motor starter or a relay must be used.

2

Image 2
Contents Instructions Table of Contents General Safety InformationComponents Installation and Sizing Considerations Standard OperationInstallation Considerations LocationPlumbing From Well Wiring Startup & Adjustment Startup & Adjustment Pressure Adjustment Precharge Adjustment Pump Protection and Diagnostics WELL-X1ERROR CodesTroubleshooting Problem Possible Cause SolutionReplacement Parts DescriptionAmtrol INC. Limited Product Warranty
Related manuals
Manual 8 pages 46.92 Kb

WELL-X1, WELL-X-TROL specifications

Amtrol's WELL-X1 and WELL-X-TROL series are advanced water storage and pressure tanks designed specifically for residential and commercial well water systems. These tanks are engineered to improve efficiency and reliability in water supply while providing a robust solution for various water needs.

One of the standout features of the WELL-X1 and WELL-X-TROL tanks is their unique diaphragm design. Unlike other tanks that rely on air pressure for water delivery, these tanks use an internal diaphragm that separates the water chamber from the air chamber. This design minimizes the risk of waterlogging, which can lead to decreased efficiency. With a constant supply of pressurized water, users experience more stable water pressure and less frequent pump cycling, ultimately extending the lifespan of the pump system.

Another key characteristic is the tanks’ construction. Both the WELL-X1 and WELL-X-TROL are made from high-quality, heavy-duty steel that is coated with a corrosion-resistant finish. This ensures durability and extends the tanks' lifespan, making them an ideal choice for both indoor and outdoor installations. Additionally, their rolled and welded construction enhances strength, ensuring that they can withstand the rigors of continuous water storage.

The WELL-X-TROL series features an integrated pressure switch, allowing for straightforward installation and added convenience. This smart design makes it easier for homeowners to manage their well system without needing extensive modifications or adjustments. Furthermore, the tanks are available in various sizes, ranging from smaller units suitable for individual homes to larger models capable of supporting multi-family dwellings or commercial applications.

In terms of performance, the WELL-X1 and WELL-X-TROL tanks excel in maintaining optimal water pressure and reducing energy consumption. This is achieved through their innovative design that minimizes cycles, allowing the pump to operate less frequently while still delivering consistent water pressure. This efficiency not only saves homeowners money on energy bills but also minimizes wear on the pump system, resulting in fewer maintenance issues.

Overall, Amtrol's WELL-X1 and WELL-X-TROL tanks represent a significant advancement in water storage technology. Their superior construction, reliable diaphragm design, and focus on energy efficiency make them a top choice for anyone seeking a dependable solution for their well water system. Whether for residential or commercial use, these tanks offer exceptional performance and peace of mind for water management.