3M CSFM1254 operating instructions Explanation of Signal Word Consequences

Page 2

SAFETY INFORMATION

Read, understand, and follow all safety information contained in these instructions prior to installation and use of the CFSM1254 Water Softener. Retain these instructions for future reference. Failure to follow installation, operation and maintenance instructions may result in property damage and will void warranty.

Intended use:

The CFSM1254 Water Softener is intended for use in softening water and has not been evaluated for other uses. The system must be installed indoors near the point of entry of a water line, and be installed by qualified professional installers according to these installation instructions.

EXPLANATION OF SIGNAL WORD CONSEQUENCES

WARNING Indicatesage. a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property dam-

CAUTION Indicates a potentially hazardous situation, which, if not avoided, may result in property damage.

WARNING

To reduce the risk associated with choking:

• Do not allow children under 3 years of age to have access to small parts during the installation of this product.

To reduce the risk associated with ingestion of contaminants:

• Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

To reduce the risk of physical injury:

• Shut off inlet water supply and depressurize system as shown in manual prior to service.

To reduce the risk associated with a hazardous voltage:

If the electrical system requires use of the cold water system as an electrical safety ground, a jumper must be used to ensure a sufficient ground connection across the fi lter installation piping — refer installation to qualified personnel.

Do not use the system if the power cord is damaged — contact qualified service personnel for repair.

To reduce the risk associated with back strain due to the heavy weight of the various system components:

• Follow safe lifting procedures.

CAUTION

To reduce the risk associated with property damage due to water leakage:

Read and follow Use instructions before installation and use of this water treatment system.

Installation and use MUST comply with existing state or local plumbing codes.

Protect from freezing, relieve pressure and drain system when temperatures are expected to drop below 33°F (0.6°C).

Do not install on hot water supply lines. The maximum operating water temperature of this filter system is 110°F (43.3°C).

Do not install systems in areas where ambient temperatures may go above 110°F (43.3°C) or below 40°F (4.4°C).

Do not install if water pressure exceeds 100 psi. If your water pressure exceeds 80 psi (552 kPa), you must install a pressure limiting valve. Contact a plumb- ing professional if you are uncertain how to check your water pressure.

Do not install where water hammer conditions may occur. If water hammer conditions exist you must install a water hammer arrester. Contact a plumbing professional if you are uncertain how to check for this condition.

Where a backfl ow prevention device is installed on a water system, a device for controlling pressure due to thermal expansion must be installed.

Do not use a torch or other high temperature sources near filter system, cartridges, plastic fittings or plastic plumbing.

On plastic fi ttings, never use pipe sealant or pipe dope. Use PTFE thread tape only, pipe dope properties may deteriorate plastic.

Take care when using pliers or pipe wrenches to tighten plastic fittings, as damage may occur if over tightening occurs.

Do not install in direct sunlight or outdoors.

Mount system in such a position as to prevent it from being struck by other items used in the area of installation.

Ensure all tubing and fi ttings are secure and free of leaks.

SHUT OFF FUEL OR ELECTRIC POWER SUPPLY TO WATER HEATER after water is shut off.

Do not install system where water lines could be subjected to vacuum conditions without appropriate measures for vacuum prevention.

Do not apply heat to any fi tting connected to Bypass or Control Valve as damage may result to internal parts or connecting adapters.

Install on a fl at/level surface. It is also advisable to sweep the floor to eliminate objects that could pierce the brine tank.

To reduce the risk associated with property damage due to plugged water lines:

Pay particular attention to correct orientation of control valve. Water flow should match arrow on control valve. The Inlet and Outlet of other water treatment equipment products will vary depending on the control valve brand used.

Image 2
Contents Installation and Operating Instructions Explanation of Signal Word Consequences Important Notes Check Your Pumping Rate and Water Pressure Locate Water Conditioning Equipment CorrectlyFacts to Remember While Planning Your Installation Important NoteInstallation Typical InstallationSoftener and Brine Tank ASSEMBLY, TOP View To reduce the risk associated with a hazardous voltageClamp Assembly Press Next and simultaneously for 3 seconds Installer Display SettingsControl Valve Programming and Regeneration Diagnostics Valve History User Display Settings General OperationMaintenance Control Valve Troubleshooting Guide Problem Possible Cause SolutionDrive Cap Assembly, Main Piston and Regenerant Piston Control Valve Service InstructionsDrive Assembly Injector Cap, Screen, Injector Plug and Injector Spacer Stack AssemblyRefill Flow Control Assembly or Refill Port Plug Water Meter or Meter PlugBypass Valve System Troubleshooting Guide Problem Cause SolutionSpecifications and Operating Data CFSM1254Parts Front Cover and Drive Assembly Drawing No Order No Description QuantityV3005 Injector Cap, Injector Screen, Injector, Plug and O-Ring Refill Flow Control Assembly Drain Line 3/4 Water Meter and Meter Plug Order No Description Fitting 1 Brass Sweat Assembly Order No Description Quantity Wrench Order No Fax

CSFM1254 specifications

The 3M CSFM1254 is a sophisticated communication headset designed specifically for industrial and construction environments where effective communication is critical. This headset combines advanced technology, comfort, and durability, making it an ideal choice for professionals who work in demanding conditions.

One of the standout features of the 3M CSFM1254 is its high-performance noise-canceling capabilities. The headset is equipped with advanced passive noise reduction technology that effectively reduces background noise, allowing users to communicate clearly even in noisy environments. This is particularly important in construction sites or manufacturing facilities where heavy machinery and equipment can create significant auditory distractions.

The 3M CSFM1254 utilizes a robust dual-ear design that provides enhanced sound isolation, further improving the user experience. The ear cups are designed for comfort, featuring cushioned padding that ensures a secure fit during extended use. This comfort, combined with an adjustable headband, allows for personalized fitting, making it suitable for all-day wear in various work situations.

Another highlight of the headset is its reliable communication capabilities. The built-in microphone is noise-canceling as well, which means that it fosters clear and effective communication by minimizing interference from surrounding noise. Users can expect consistent audio quality, enabling them to stay connected with colleagues and supervisors without the frustration of interrupted or inaudible conversations.

Durability is a defining characteristic of the 3M CSFM1254. It is constructed with high-quality materials that can withstand the rigors of challenging work environments. The headset has been tested for various impacts and environmental conditions, making it a reliable choice for those who need equipment that can keep up with their demanding work routines.

In terms of connectivity, the 3M CSFM1254 offers versatile options, allowing it to be easily integrated with various communication systems, including two-way radios and smartphones. This flexibility enhances workplace communication efficiency, enabling teams to coordinate tasks and safety measures effectively.

Overall, the 3M CSFM1254 headset stands out as a top choice for professionals who require reliable, clear communication and durability in their headsets. With its combination of noise-canceling technology, comfort, and robust build, it addresses the needs of those working in high-noise environments, ensuring they remain connected and safe while performing their tasks.