3M CSFM1254 Control Valve Programming and Regeneration, Installer Display Settings

Page 9

SECTION 3: CONTROL VALVE PROGRAMMING AND REGENERATION

Grains Capacity/lb NaCl

6,000 to 3,000

 

 

 

Lbs NaCl/cu ft resin2

Less than 7.5

 

Backwash Normal

8

 

 

 

 

Regenerate

60

Cycle Time

 

 

Backwash Normal

10

in Minutes

 

 

Rinse

8

 

 

 

 

 

Total3

86

 

 

 

WS1 & WS 1.25 Downflow

Regenerant Refill After Rinse

1st Cycle

Backwash

 

 

2nd Cycle

Regenerate

 

 

3rd Cycle

Backwash

 

 

4th Cycle

Rinse

 

 

5th Cycle

Fill Dissolve

 

 

6th Cycle

Service

 

 

Step 1

Step 2

Step 3

Step 4

Step 5

RETURN TO

NORMAL MODE

Installer Display Settings

(Step 1) Press NEXT and simultaneously for 3 seconds.

(Step 2) Hardness: Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons. The default is 20 with value ranging from 1 to 150 in 1 grain increments. Note: The grains per gallon can be increased if soluble iron needs to be reduced. Press NEXT to go to Step 3. Press REGEN to exit Installer Display Settings.

(Step 3) Day Override: Day Override sets the number of days between regenerations and sets the maximum number of days between regenerations. If value is set as a number (allowable range from 1 to 28) a regeneration initiation will be called for on that day even if sufficient number of gallons were not used to call for a regeneration. Set Day Override using or buttons.

number of days between regeneration (1 to 28); or “OFF”. Press NEXT to go to Step 4. Press REGEN to return to previous step.

(Step 4) Next Regeneration Time (hour): Set the hour of day for regeneration using or buttons. AM/PM toggles after 12. The default time is 2:00 a.m. Press NEXT to go to Step 5. Press REGEN to return to previous step.

(Step 5) Next Regeneration Time (minutes): Set the minutes of day for regeneration using or buttons. Press NEXT to exit Installer Display Settings. Press REGEN to return to previous step.

To initiate a manual regeneration immediately, press and hold the “REGEN” button for three seconds. The system will begin to regeneration immediately. The control valve may be stepped through the various regeneration cycles by pressing the “REGEN” button.

Power Lost

If power goes out for less than two hours, the system will automatically reset itself. If an extended power outage occurs, the time of day will flash on and off which indicated the time of day should be reset. The system will remember the rest.

Error Message

If the word “error” and a number are alternately flashing on the display contact the “Technical Support Services Department” at CUNO Incorporated, phone number 1-866-693-2543 for help. This indicates that the valve was not able to function properly.

3-1

Image 9
Contents Installation and Operating Instructions Explanation of Signal Word Consequences Important Notes Locate Water Conditioning Equipment Correctly Check Your Pumping Rate and Water PressureImportant Note Facts to Remember While Planning Your InstallationTypical Installation InstallationTo reduce the risk associated with a hazardous voltage Softener and Brine Tank ASSEMBLY, TOP ViewClamp Assembly Installer Display Settings Control Valve Programming and RegenerationPress Next and simultaneously for 3 seconds Diagnostics Valve History General Operation User Display SettingsMaintenance Problem Possible Cause Solution Control Valve Troubleshooting GuideControl Valve Service Instructions Drive AssemblyDrive Cap Assembly, Main Piston and Regenerant Piston Refill Flow Control Assembly or Refill Port Plug Spacer Stack AssemblyInjector Cap, Screen, Injector Plug and Injector Water Meter or Meter PlugBypass Valve Problem Cause Solution System Troubleshooting GuideCFSM1254 Specifications and Operating DataParts Drawing No Order No Description Quantity Front Cover and Drive AssemblyV3005 Injector Cap, Injector Screen, Injector, Plug and O-Ring Refill Flow Control Assembly Drain Line 3/4 Water Meter and Meter Plug Order No Description Fitting 1 Brass Sweat Assembly Order No Description Quantity Wrench Order No Fax

CSFM1254 specifications

The 3M CSFM1254 is a sophisticated communication headset designed specifically for industrial and construction environments where effective communication is critical. This headset combines advanced technology, comfort, and durability, making it an ideal choice for professionals who work in demanding conditions.

One of the standout features of the 3M CSFM1254 is its high-performance noise-canceling capabilities. The headset is equipped with advanced passive noise reduction technology that effectively reduces background noise, allowing users to communicate clearly even in noisy environments. This is particularly important in construction sites or manufacturing facilities where heavy machinery and equipment can create significant auditory distractions.

The 3M CSFM1254 utilizes a robust dual-ear design that provides enhanced sound isolation, further improving the user experience. The ear cups are designed for comfort, featuring cushioned padding that ensures a secure fit during extended use. This comfort, combined with an adjustable headband, allows for personalized fitting, making it suitable for all-day wear in various work situations.

Another highlight of the headset is its reliable communication capabilities. The built-in microphone is noise-canceling as well, which means that it fosters clear and effective communication by minimizing interference from surrounding noise. Users can expect consistent audio quality, enabling them to stay connected with colleagues and supervisors without the frustration of interrupted or inaudible conversations.

Durability is a defining characteristic of the 3M CSFM1254. It is constructed with high-quality materials that can withstand the rigors of challenging work environments. The headset has been tested for various impacts and environmental conditions, making it a reliable choice for those who need equipment that can keep up with their demanding work routines.

In terms of connectivity, the 3M CSFM1254 offers versatile options, allowing it to be easily integrated with various communication systems, including two-way radios and smartphones. This flexibility enhances workplace communication efficiency, enabling teams to coordinate tasks and safety measures effectively.

Overall, the 3M CSFM1254 headset stands out as a top choice for professionals who require reliable, clear communication and durability in their headsets. With its combination of noise-canceling technology, comfort, and robust build, it addresses the needs of those working in high-noise environments, ensuring they remain connected and safe while performing their tasks.