Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve

 

TDB3104, WF3204

Installation Instructions

Installation Instructions continued . . .

NOTE: The Vernatherm TMA valve is NOT factory preset. Upon installation, the temperature of this valve must be checked and adjusted to ensure delivery of a safe water temperature. Water in

excess of 110°F (43°C) may cause scalding.

5.Check the temperature when approximately 1.0 GPM water flow is reached and adjust if neces- sary (the range of the valve is 95°F–115°F (35°C–43°C). To adjust the temperature, follow the procedure below:

Loosen temperature locking nut with wrench.

Using a blade screwdriver, turn the adjustment stem counterclockwise to increase the tempera- ture or clockwise to decrease the temperature (Figure 13).

Once desired temperature is reached, tighten nut to prevent temperature change.

6.Clean sprayhead if necessary. See page 24 for sprayhead maintenance and repair parts. Adjust the volume control valve, if necessary, to control the flow of water.

7.Attach pedestal access panel with hardware provided.

8.Attach kick plate to pedestal base with hardware provided.

TEMPERATURE

TEMPERATURE

ADJUSTMENT

LOCKING

STEM

NUT

Figure 13

18

2/8/07

Bradley Corporation • 215-1470 Rev. H; EN 06-915

Image 18 Contents
Installation Instructions Table of ContentsPre-Installation Information Supplies required for installationCylindrical air valve Semi-Circular Washfountain Dimensions Model TDB3104 Semi-circular side viewSemi-Circular Washfountain Dimensions juvenile height Pedestal accessModel WF3204 Semi-circular side view Rough-In Specifications Type a DrainType B Drain Type H Drain Type O DrainInstallation Instructions Installing the drainBowl/pedestal mounting and assembly TAS OptionInstalling drain spud in bowl Tie Pipe OptionShown TOP Cover Tube Section View Unit Assembly Module Cover Assembly Valve Assembly S45-2246 Valve and Tubing Connections Valve and Tubing Connections AIR Metering Valve OptionSprayhead Male Tube Connector NUT Tubing Excess of 110F 43C may cause scalding Cleaning/Maintenance Instructions for Terreon Cleaning/Maintenance Instructions for Gel-coated FiberglassSpecial Situations for Material Cleaning and Maintenance Instructions for Stainless Steel Soap Valve Liquid S09-007S Parts List Soap Valve Lotion S09-057S Parts ListParts List Soap Valve Powdered S09-010ASoap Maintenance Tips Problem Water flow diminishes from the sprayhead Sprayhead Service SuggestionsProblem Water splashes over the rim of the bowl Sprayheads Standard w/Neoprene Spray Ring GrommetActuator Module Components Tube Connection LeaksAST4 Valve Repair Kits AST4 Valve Repair KitsMetering Air Valve Troubleshooting Thermostatic Mixing Valve Troubleshooting Problem Limited water flowProblem External leaks in the system Vernatherm Thermostatic Mixing Valve S01-524 Repair Kit S65-259