Terreon® 54" Semi-circular Washfountain with Cylindrical Air Valve

 

TDB3104, WF3204

Installation Instructions

Installation Instructions

Step 1: Installing the drain

1.Rough in supply and drain piping as required for your installation (see pages 6-7 for rough-ins of the optional installations).

2.Assemble the drain to the dimension shown in Figure 3 for the bowl you are installing.

NOTE: All piping shown in dotted lines to be supplied by installer.

 

 

Types B, H

 

Vent

 

 

or

Vented Trap

 

Tie Pipe

2" NPT Coupling if Tie

(111-024)

(Supplied by Installer)

 

Pipe is not required

 

 

(Supplied by Installer)

 

 

Centerline Washfountainof

 

 

 

Centerline

 

 

 

 

Washfountain

 

 

 

 

of

 

B – See

Table

1

 

 

 

 

 

 

 

 

4"

 

 

Vent

 

 

or

 

(102)

 

 

 

 

 

 

Tie Pipe

(Supplied by Installer)

 

 

 

Table

1

B

– See

 

 

 

4"

 

 

 

 

 

 

(102)

 

 

 

Optional

Tie Pipe Bracket (S70-082)

Types A, O

Centerline

 

Washfountain

 

 

of

See rough-ins on Pages 6-7 for dimensions not shown

Figure 3

Table 1 — “B” Trap Dimensions

Dim

Standard Height

Juvenile Height

B

23-3/8" (594mm)

22-1/2" (572mm)

 

 

 

 

 

 

Table

1

B – See

 

 

 

 

 

 

4" (102)

Types A, O

With Tie Pipe

Bracket Option

TAS

24-1/2" (622mm)

8

2/8/07

Bradley Corporation • 215-1470 Rev. H; EN 06-915

Image 8 Contents
Installation Instructions Table of ContentsCylindrical air valve Pre-Installation InformationSupplies required for installation Semi-Circular Washfountain Dimensions Model TDB3104 Semi-circular side view Semi-Circular Washfountain Dimensions juvenile height Pedestal accessModel WF3204 Semi-circular side view Type B Drain Rough-In SpecificationsType a Drain Type H Drain Type O DrainInstallation Instructions Installing the drainBowl/pedestal mounting and assembly TAS OptionInstalling drain spud in bowl Tie Pipe OptionShown TOP Cover Tube Section View Unit Assembly Module Cover Assembly Valve Assembly S45-2246 Valve and Tubing Connections Valve and Tubing Connections AIR Metering Valve OptionSprayhead Male Tube Connector NUT Tubing Excess of 110F 43C may cause scalding Special Situations for Material Cleaning/Maintenance Instructions for TerreonCleaning/Maintenance Instructions for Gel-coated Fiberglass Cleaning and Maintenance Instructions for Stainless Steel Soap Valve Liquid S09-007S Parts List Soap Valve Lotion S09-057S Parts ListParts List Soap Valve Powdered S09-010ASoap Maintenance Tips Sprayhead Service Suggestions Problem Water splashes over the rim of the bowlProblem Water flow diminishes from the sprayhead Sprayheads Standard w/Neoprene Spray Ring GrommetActuator Module Components Tube Connection LeaksAST4 Valve Repair Kits AST4 Valve Repair KitsMetering Air Valve Troubleshooting Problem External leaks in the system Thermostatic Mixing Valve TroubleshootingProblem Limited water flow Vernatherm Thermostatic Mixing Valve S01-524 Repair Kit S65-259