Bradley Smoker S53-307, S53-308, 232-007 Changing Faucet Operation, Faucet Range, Faucet Mode

Page 6

Aerada 1000 Series Gooseneck FaucetInstallation Instructions

Faucet Operation

Operating Modes

• Water Saver Mode: water flows for a maximum of

• Normal Motion Detecting Mode: water flows within 1/4

5 seconds starting from first hand detection and

second after activating sensor (i.e., putting hands in

immediately turns off when hands are removed.

front of collar) and continues to stay on as long as

Additional Operating Features

motion is detected. Maximum time is 45 seconds

12-second, no-motion turn off in normal mode

(factory default setting).

• “Low battery” indication

• Scrub Mode: water continues to flow for 60 seconds

• Battery life up to one year depending on frequency

(default) after deactivating the sensor (removing

of use.

hands).

 

• Metered Mode: water flows for 10 seconds (default)

 

from first hand detection.

 

Changing Faucet Operation

In order to change any faucet option, the DIPswitch must be used (located inside the electronics cover assembly, see illustration this page).

Checking/Changing DIPswitch Settings

1.Remove the electronics cover (1) from the baseplate

(2).

2.Lift the partition (3) out to expose the circuit board and DIPswitch.

3.To change a DIPswitch setting, use a small pointed object to move the appropriate DIPswitch to ON or OFF.

Faucet range and mode settings along with their corresponding DIPswitch settings are outlined in Table 1 and Table 2

Resetting Faucet Electronics

In order to reset the faucet electronics, a reset button located inside the electronics cover assembly must be pushed in (see illustration this page).

 

3

 

 

1

2

 

 

 

 

DIPSWITCHES

MANUAL

ON

ON

 

RESET

OFF

 

1 2 3 4 5

 

BUTTON

 

OFF

 

 

1 2 3 4 5

To reset faucet electronics:

1.Remove hex screw holding the electronics cover to the baseplate and remove cover.

2.Lift the partition out to expose the circuit board and reset button.

3.Make sure there are no objects in front of the collar sensor, then push the button to reset.

4.Wait 30 seconds for faucet to automatically calibrate to the environment.

5.Activate water flow by placing your hand in front of the sensor.

6.Place partition into the electronics cover.

7.Place the electronics cover onto the baseplate and secure with the hex screw.

NOTE: Resetting the faucet electronics causes loss of virtual settings and time in use, and will also start the 8-minute timer where the LED on the electronics box will blink and an audible indicator chirps twice per second whenever hand presence is detected.

Electronics Cover Assembly & DIPswitch

Range

Short

Normal

Far

 

Maximum

 

 

 

 

 

 

 

 

 

Switch 1

off

on

on

 

off

 

 

 

 

 

 

 

 

 

Switch 2

off

off

on

 

on

 

 

 

 

 

 

 

 

 

 

 

Table 1 - Faucet Range

 

 

 

 

 

 

 

 

 

 

 

 

Normal

 

Scrub

 

Meter

Water Saver

Modes

 

Mode

 

Mode

 

Mode

 

Mode

 

 

 

 

 

 

 

 

 

Switch 3

 

off

 

on

 

off

 

off

 

 

 

 

 

 

 

 

 

Switch 4

 

off

 

off

 

on

 

off

 

 

 

 

 

 

 

 

 

Switch 5

 

off

 

off

 

off

 

on

 

 

 

 

 

 

 

 

 

Table 2 - Faucet Mode

6

9/23/04

Bradley Corporation • 215-1559 Rev. A; EN 04-216A

Image 6
Contents Installation Instructions Table of Contents Supplies Required for InstallationComponents for Aerada 1000 Series Faucet Installation Instructions Single Hole and Cover Plate Directly to Installation SolenoidOptional Valves, Models S53-308 and S53-309 Installation Instructions Electronic Battery Box DC Models S53-306 and S53-307Electrical connections are made Changing Faucet Operation Faucet ModeFaucet Operation Faucet RangeTroubleshooting BeepBeeps For the sensor and solenoid cables pages 4