Bradley Smoker 232-007, S53-308, S53-307, S53-309, S53-306 Troubleshooting, Beeps

Page 7

Installation InstructionsAerada 1000 Series Gooseneck Faucet

Troubleshooting

Whenever new batteries are installed, AC power is applied,

 

The following chart provides details concerning the number

or a manual reset button is pressed, the LED on the

 

of beeps and possible errors associated with them .

electronics cover will blink and an audible indicator chirps

 

1

Beep:

Indicates low battery.

twice per second whenever hand presence is detected.

 

After 8 minutes, the LED and buzzer function stops.

 

2

Beeps:

Calibration out of range (environment too

 

 

If an error occurs, the LED will blink and the buzzer will

 

 

 

reflective).

sound every 30 seconds to assist in diagnosing the

 

3

Beeps:

Room infrared level out of range; too much

problem. When corrective action is taken the LED and

 

 

 

 

sunlight, heat lamp present, etc.

buzzer will stop.

 

 

 

 

 

 

 

 

 

4

Beeps:

Solenoid short circuit.

 

 

 

5

Beeps:

Solenoid unplugged or loose/broken solenoid

 

 

 

 

connection.

 

 

Refer to Troubleshooting Chart below and on page 8 for

 

 

further troubleshooting information.

 

 

 

 

 

Problem

Check

Possible Solution

 

 

 

Water runs continuously.

Debris in solenoid (no beeps).

Disassemble solenoid and inspect/clean parts.

 

 

 

 

Water pressure too high (no beeps).

Reduce pressure to under 80 PSI.

 

 

 

Faucet turns on by itself

Incorrect range setting for spout type and

Change range setting using DIPswitch (page 6).

(ghosting).

sink used (2 beeps).

 

 

 

 

No water flow.

Water not turned on (no beeps).

Turn on water supply.

 

 

 

 

Solenoid cable not connected to

Check connection.

 

electronics cover (5 beeps).

 

 

 

 

 

Solenoid short circuit (4 beeps).

Replace electronics cover.

 

 

 

 

Sensor cable not connected to electronics

Check connection.

 

cover (no beeps).

 

 

 

 

 

Inoperative sensor (no beeps).

Inspect collar wiring for signs of damage or corrosion.

 

 

Replace if necessary.

 

 

 

 

Inoperative electronics cover assembly

Replace cover assembly.

 

(no beeps).

 

 

 

 

 

Water pressure too high (no beeps).

Reduce pressure to under 80 PSI.

 

 

 

 

Low battery voltage (DC only) (1 beep).

Replace batteries (DC only).

 

 

 

 

6VDC transformer not properly connected

Use correctly sized terminal clips (page 4).

 

to partition assembly (no beeps).

 

 

 

 

 

Wiring of multiple unit 6VDC transformer

Faucets must be wired in parallel from transformer

 

(no beeps).

(transformer to each individual unit), not connected in

 

 

a series.

 

 

 

Range too short or too long.

Interference during automatic calibration

Remove interference; reset electronics using reset

 

(no beeps).

button (page 6). Allow 30 seconds for faucet to

 

 

automatically re-calibrate.

 

 

 

 

Incorrect range setting for type of spout

Change range setting using DIPswitch (page 6).

 

and sink used.

 

 

 

 

 

Lighting environment affecting sensor

Change range setting using DIPswitch (page 6).

 

(3 beeps).

 

 

 

 

Bradley Corporation • 215-1559 Rev. A; EN 04-216A

9/23/04

7

Image 7
Contents Installation Instructions Supplies Required for Installation Table of ContentsComponents for Aerada 1000 Series Faucet Directly to Installation Solenoid Installation Instructions Single Hole and Cover PlateOptional Valves, Models S53-308 and S53-309 Models S53-306 and S53-307 Installation Instructions Electronic Battery Box DCElectrical connections are made Faucet Range Faucet ModeFaucet Operation Changing Faucet OperationBeep TroubleshootingBeeps For the sensor and solenoid cables pages 4