American Standard 3475.5 Install Handles, Test Installed Fitting, Check Drain Connections

Page 4

11 INSTALL HANDLES

LEVER HANDLE

Turn HANDLE STEM (1) to "OFF" position.

Place the HANDLE ADAPTER (2) on the HANDLE STEM (1). Install the ADAPTER SCREW (3) and tighten securely.

Position LEVER HANDLE (4) and place on ADAPTER (2). Install the HANDLE SCREW (5) and tighten securely.

4

5

3

2

1

12 TEST INSTALLED FITTING

With HANDLES (1) in OFF position, turn on WATER SUPPLIES (2) and check all connections for leaks.

Operate both HANDLES (1) to flush water lines thoroughly.

Rotate TRANSFER VALVE (5) from rim wash to spray several times to check operation.

OUTLINE OF BIDET

1

 

3

1

13 CHECK DRAIN CONNECTIONS

 

 

Pull up POP-UP KNOB (3) and fill Sink with water. Check

4

 

that DRAIN STOPPER (4) makes a good seal and retains

2

water in Bidet. If STOPPER (4) does not seal properly,

 

 

 

please refer to “Troubleshooting Guide” in these instructions.

SPRAY

 

Push POP-UP KNOB (3) down and check all drain

 

connections and "P" trap for leaks. Tighten

 

if necessary.

 

2

14 CARE INSTRUCTIONS:

DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.

DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A CLOTH WITH A COARSE SURFACE.

15

SERVICE

 

 

To change direction of handle

 

 

 

rotation, proceed as follows:

 

 

Turn VALVE to OFF position.

1

 

Loosen HANDLE SCREW (1) .

 

2

Pull HANDLE (2) off ADAPTER (4). Loosen

ADAPTER

3

SCREW (3) and pull off ADAPTER (4).

 

Remove SPRING CLIP (7). Lift STOP WASHER (5),

 

turn 90° and replace. Replace SPRING CLIP (7).

4

Reinstall ADAPTER SCREW (4) and LEVER HANDLE (2).

 

Tighten HANDLE SCREW (1).

 

90˚

If spout drips, operate handles several

 

5

 

6

times from OFF to ON position. Do not

 

force - handles turn only 90˚.

7

M 9 6 8 6 7 7 R e v . 1 . 1

4

Image 4
Contents Spray Installation Bidet Faucet InstallationBidet Faucet and Transfer Valve With Speed Connect Drain Install Drain from Tighten Locknut Below Fixture POP-UP ROD AssemblyPOP-UP Drain Remove FlangeConnector Install Diverter KnobAttach Cable Check Operation of POP-UPTest Installed Fitting Install HandlesCheck Drain Connections Troubleshooting Guide Cable Adjustment ProcedureLocked Mode Vandal Proof Unlocked Mode Fig. G3475.501 Bidet Faucet and Transfer ValveInstall Drain from Attach Cable Connector EverClean Finish Care Instructions SpeedConnect Drain Locked Mode Vandal Proof Unlocked Mode