Installation
Instructions
COLONY/COLONY SOFT | 3475.301 |
Bidet Faucet and Transfer Valve | 3475.501 |
with SpeedConnect™ Drain
Congratulations on purchasing your American Standard faucet with Speed Connect drain, a feature found only on American Standard faucets.
SpeedConnect Drain*
•Fewer parts, installs in less time
•Never needs adjustment
•Guaranteed to seal properly the first time, every time.
Certified to comply with ANSI A112.18.1
M968796 Rev. 1 . 1
*Your new American Standard faucet is designed to work only with the SpeedConnect drain.
To ensure that your installation proceeds
|
| 8 TO 12 | |||
| TRANSFER VALVE | FINISHED |
|
| |
| WALL |
|
| ||
| (FOR FLUSHING |
|
| ||
|
|
|
| ||
BIDET OUTLINE | RIM OR SPRAY) |
|
|
| |
|
|
| (C) | (H) | |
IS SYMBOLIC | 7/8 DIA. |
| |||
DOUCHE ADJ. |
|
|
| ||
|
| ||||
SPRAY | TO | DIA. |
|
| |
|
|
|
| ||
DIA. |
|
|
|
| |
|
|
|
| FINISHED |
|
|
| FLOOR |
| ||
|
|
|
|
DIVERTER AND
VACUUM BREAKER
ASSEMBLY
FOR GROUND JOINT CONNECTION OR 1/2 " O.D. SLIP (INLETS)
REAR VIEW WITH
WALL REMOVED
Required tools
Screwdriver | Plumbers' Putty or |
| Caulking |
Phillips Screwdriver |
|
| Channel Locks |
Adjustable Wrench
Tubing Cutter
1 |
|
| Turn off hot and cold water |
| ||
BIDET FAUCET INSTALLATION | CAUTION |
| ||||
supplies before beginning. |
| |||||
Place RUBBER RING (10) into ADAPTER (4). |
| |||||
|
|
|
|
| ||
|
|
|
|
| ||
|
|
|
|
| ||
|
|
| Install LOCKNUT (1) and RUBBER WASHER (2) onto VALVE BODIES (3, 3a). From |
| ||
|
|
|
| |||
|
|
| under side of mounting surface, install VALVE BODY (3, 3a) through valve mounting | 4 | ||
|
|
| holes. Threads of VALVE BODY (3, 3a) should extent at least 5/16 of a inch above | |||
|
|
|
| |||
|
|
| mounting surface top. Fig. A. Thread ADAPTER (4) onto VALVE BODIES (3, 3a) | 10 | ||
|
|
| until snug against internal stop. If necessary, adjust LOCKNUT (1). |
|
11
6
7
BIDET
LEDGE
Tighten LOCKNUTS (1) with WRENCH (5) (supplied) to secure VALVE BODIES (3, 3a).
Remove MOUNTING NUT (6), WASHER (7) and UPPER GASKET (8) from TRANSFER VALVE (9). Insert TRANSFER VALVE (9) into the center forward hole of BIDET.
Replace UPPER GASKET (8) and WASHER (7) . Position the side threaded outlet rearward and secure MOUNTING NUT (6). Thread ESCUTCHEON (11) onto TRANSFER VALVE (9) until it seats against the BIDET LEDGE.
Fig. A. | 4 |
| |
10 |
| ||
|
| ||
5/16'' | MOUNTING | ||
MIN. | |||
SURFACE |
| ||
| 2 | ||
|
| ||
| 2 | 1 | |
| 1 |
| |
3, 3a |
| 5 |
| 3 | 3a |
|
| |
HOT |
| COLD |
8
9
2 SPRAY INSTALLATION
8 | 2 | 9 |
7 | PUTTY | 1 |
Assemble SPRAY BODY (1) to BIDET. Using putty, seal underside of SPRAY BODY FLANGE (2) and secure with NUT (3).
6
3
Thread SPRAY HOSE (4) with SEAL WASHER (5) to SPRAY BODY (1). Connect other end of HOSE (4) with SEAL WASHER (6) to side outlet NIPPLE (7) of the TRANSFER VALVE (8).
Thread SPRAY CAP (9) onto SPRAY BODY (1).
4 | 5 |
| |
| 4 |
1