036-21544-001 Rev. B (1103)

14 PARTS BREAKDOWN

MODELS 36 AND 42

NOTE

:

FIG

ITEM

DESCRIPTION

 

PUGH036AYB

PUGH042AYB

<

 

 

 

 

 

 

 

1

1

Compressor, Hermetic

 

015-03425-001

015-02773-004

 

1

2

Accumulator

 

 

026-35435-000

026-35435-000

 

1

3

Compensator Tank

 

026-35433-000

026-35434-000

 

1

4

Valve, Reversing

 

025-31922-000

025-31929-000

 

1

5

Coil, Solenoid

 

 

1456-9761

1456-9761

 

1

6

Guard, Coil

 

 

373-20091-010

373-20091-010

 

1

7

Control, Low Pressure

 

025-38610-000

025-38610-000

 

(7 psi- open / 22 psi close)

 

 

 

 

 

 

 

 

1

8

Filter Drier

 

 

6536-3341

6536-3341

 

1

9

Control, High Pressure

 

025-33305-048

025-33305-048

 

(400 psi- open / 300 psi close)

 

 

 

 

 

 

 

 

1

10

Distributor

 

 

022-09060-000

022-09059-000

 

1

11

Sensor, Coil (Liquid Replacement)

 

025-31994-000

025-31994-000

 

1

12

Valve, Liquid (1/2” FL x 3/8” SW)

 

022-09063-000

022-09057-000

 

1

13

Valve, Suction (3/4” FL x 3/4” SW)

 

022-09049-750

---

 

Valve, Suction (7/8” FL x 3/4” SW)

 

---

022-09052-875

 

 

 

 

 

1

14

Crankcase Heater

 

---

025-38695-000

 

1

15

Isolator, Compressor (Pkg. of 4)

 

9435-1081

9435-1081

 

1

16

Fastener, Push-in (4 Req’d)

 

021-18381-000

021-18381-000

 

1

17

Base, Pan

 

 

2260-1011

2260-1011

 

1

18

Mesh, Coil Guard Plastic

 

028-14728-000

028-14731-000

 

1

19

Coil, Condenser

 

 

373-20075-205

373-20075-204

 

1

20

Hubcap

 

 

026-39292-000

026-39292-000

 

1

21

Motor Mount Kit (Acorn Nuts)

 

363-90117-700

363-90117-700

 

1

22

Guard, Fan

 

 

026-35511-022

026-35511-022

 

1

23

Motor, Fan

 

 

024-27596-000

024-27596-000

 

1

24

Wireway, (Electric Channel)

 

028-13216-000

028-13216-000

 

1

25

Blade, Fan (18”)

 

026-34593-000

026-34593-000

 

1

26

Panel, Top

 

 

2260-1021/A

2260-1021/A

 

1

27

Plate, Block-Off

 

 

2260-1081/B

2260-1081/B

 

1

28

Cover, Electric Box

 

2218-1151/A

2218-1151/A

 

1

29

Diagram, Wiring

 

 

035-18739-001

035-18739-001

 

1

30

Block, Terminal

 

 

025-38589-003

025-38589-003

 

1

31

Electrical Plug

 

 

025-33306-006

025-33306-006

 

1

32

Ground Lug

 

 

025-21798-000

025-21798-000

 

1

33

Capacitor, Run

(45/5MFD)

[RC]

024-25895-000

---

 

Capacitor, Run

(60/5MFD)

[RC]

---

024-25033-000

 

 

 

 

1

34

Relay

 

 

024-24116-000

024-24116-000

 

1

35

Transformer (40VA)

 

025-18452-000

025-18452-000

 

1

36

Contactor, Electrical (30 amp)

[M]

024-27531-000

024-27531-000

 

1

37

Control, Defrost

 

 

031-01976-000

031-01976-000

 

*

38

Harness, Compressor

 

025-31884-000

025-31884-000

 

*

39

Nameplate, Bezel

 

035-13508-000

035-13508-000

 

*

40

Harness, Wiring (3 Wire)

 

373-20055-006

373-20055-006

 

*

41

Harness, Wiring (8 Wire)

 

373-20055-007

373-20055-007

 

*Not Shown

New replacement parts shown in bold face type at the first printing of parts list dated 4/03. Major components and suggested stocking items are shown with shaded item number. “<“ Across from row indicates a change in that row.

--- Not applicable to specified model.

TO ORDER AUTHORIZED FACTORY REPLACEMENT PARTS - Contact your local Mitsubishi Electric distributor. or visit our website at www.mrslim.com for a Distributor and Dealer listing.

Mitsubishi Electronics 2003

35

Image 35
Contents Pugh Outdoor Unit Applies to Voltage Phase SuffixCapacity Correction Factors for Description and FeaturesPkgh Series Heat Pump Systems SpecificationsElectrical Specifications Heat Pump Units Pcgh Series Heat Pump SystemsModels PCH24GK PCH30GK PCH36GK PCH42GK Standard Operating DataPCH Indoor Units with Pugh Outdoor Units Models PKH18FK PKH24FK PKH30FK PKH36FK PKH Indoor Units with Pugh Outdoor UnitsModels PLH18GK PLH24GK PLH30GK PLH36GK PLH42GK PLH Indoor Units with Pugh Outdoor UnitsPCH24GK+PUGH24 Indoor Air = 810 CFM Performance Data Operating Pressures CoolingPCH30GK+PUGH30 Indoor Air = 1130 CFM PCH36GK+PUGH36 Indoor Air = 1130 CFM PCH42GK+PUGH42 Indoor Air = 1130 CFM PKH18FK+PUGH18 Indoor Air = 640 CFM PKH24FK+PUGH24 Indoor Air = 640 CFM PKH30FK+PUGH30 Indoor Air = 910 CFM PKH36FK+PUGH36 Indoor Air = 885 CFM PLH18AK+PUGH18 Indoor Air = 670 CFM PLH24AK+PUGH24 Indoor Air = 950 CFM PLH30AK+PUGH30 Indoor Air = 1020 CFM PLH36AK+PUGH36 Indoor Air = 1020 CFM PLH42AK+PUGH42 Indoor Air = 1100 CFM PKH24FK/PUGH24 Performance Data Operating Pressures HeatingPKH18FK/PUGH18 PKH30FK/PUGH30PLH36AK/PUGH36 PLH18AK/PUGH18PLH24AK/PUGH24 PLH30AK/PUGH30PCH42GK/PUGH42 PCH24GK/PUGH24PCH30GK/PUGH30 PCH36GK/PUGH36Typical Installation Dimensions and ClearancesSuperheat Charging Method Operating Pressures / Superheat System ChargeMeasurement Method Operating Pressures / Superheat Temperature and PressureOperating Range Operating Temperature RangeCHARGE, OZ Model Liquid OD Vapor OD CHARGE, OZ/FTFactory Charge ADD Charge ARI Rating Point Model Model Refrigerant Piping Length ONE WAY Capacity Correction Factors for Various Pipe LengthsCOOLING/HEATING Operation Microprocessor ControlLED Flashes Indication of Condition Electrical Refrigerant System Service PortsParts Breakdown Description PUGH018AYB PUGH024AYB PUGH030AYB Models 18, 24,Description PUGH036AYB PUGH042AYB Models 36Mitsubishi Electronics 036-21544-001 Specifications are subject to change without notice