Mitsubishi Electronics PUGH36AYB, PUGH42AYB, PUGH24AYB PLH Indoor Units with Pugh Outdoor Units

Page 6

036-21544-001 Rev. B (1103)

3 STANDARD OPERATING DATA

PLH INDOOR UNITS WITH PUGH OUTDOOR UNITS

MODELS

 

 

PLH18GK

PLH24GK

PLH30GK

PLH36GK

PLH42GK

Item

 

Unit

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

Cooling

Heating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage

 

V

208/230

208/230

208/230

208/230

208/230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuit

Frequency

 

Hz

60

60

60

60

60

60

60

60

60

60

 

 

 

 

 

 

 

 

 

 

 

 

 

Total Input

 

kW

1.92

1.55

2.74

2.33

3.14

2.79

3.57

3.32

4.06

4.10

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical

Indoor Fan Current

 

A

0.6

0.6

0.6

0.5

1.0

1.0

1.0

1.0

1.2

1.2

 

 

 

 

 

 

 

 

 

 

 

 

 

Booster Heater Current

 

A

--

7.6/8.4

--

7.6/8.4

--

7.6/8.4

--

7.6/8.4

--

7.6/8.4

 

 

 

 

 

 

 

 

 

 

 

 

 

Outdoor Fan Current (FLA)

 

A

0.5

0.5

0.5

0.5

1.4

1.4

1.3

1.3

1.3

1.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compressor Current (230v)

 

A

7.6

6.2

10.6

8.9

12.5

10.1

17.3

16.3

17.3

16.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensing Pressure

 

PSIG

280

163

276

212

275

245

267

242

267

255

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Circuit

Suction Pressure

 

PSIG

87

53

78

55

76

55

78

57

67

54

 

 

 

 

 

 

 

 

 

 

 

 

 

Discharge Temperature

 

°F

171

122

184

183

185

161

185

139

172

157

 

 

 

 

 

 

 

 

 

 

 

 

 

Condensing Temperature

 

°F

110

48

111

84

110

82

106

77

107

95

Refrigerant

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suction Temperature

 

°F

70

38

64

46

67

43

67

32

49

33

 

 

 

 

 

 

 

 

 

 

 

 

Compressor Shell Bottom Temperature

°F

146

103

103

137

148

97

122

74

122

74

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant Pipe Length

 

FT.

25

25

25

25

25

25

25

25

25

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Refrigerant Charge

 

-

4 lbs

0 oz

6 lbs

4 oz

4 lbs

15 oz

6 lbs

0 oz

7 lbs

5 oz

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Intake Air Temperature

DB

°F

80

70

80

70

80

70

80

70

80

70

 

 

 

 

 

 

 

 

 

 

 

 

 

Side

WB

°F

67

60

67

60

67

60

67

60

67

60

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Discharge Air Temperature

DB

°F

60

95

62

94

52

97

59

103

56

110

Indoor

 

 

 

 

 

 

 

 

 

 

 

 

WB

°F

58

--

59

--

59

--

57

--

55

--

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Speed

 

RPM.

1490

1490

1490

1490

1480

 

 

 

 

 

 

 

 

 

 

 

 

Airflow (High)

 

CFM

670

950

1020

1020

28400

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Side

Intake Air Temperature

DB

°F

95

47

95

47

95

47

95

47

95

47

 

 

 

 

 

 

 

 

 

 

 

 

WB

°F

--

43

--

43

--

43

--

43

--

43

 

Outdoor

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fan Speed

 

RPM.

1050

1050

1100

850

1050

 

 

 

 

 

 

 

 

Airflow (High)

 

CFM

1750

1950

2650

3125

3250

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Capacity

 

BTU/H

19200

19200

24400

24200

27800

30200

35200

36400

40000

45000

 

 

 

 

 

 

 

 

 

 

 

 

 

SHF

 

--

0.78

--

0.79

--

0.76

--

0.72

--

0.66

--

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

Mitsubishi Electronics 2003

Image 6
Contents Applies to Voltage Phase Suffix Pugh Outdoor UnitDescription and Features Capacity Correction Factors forPcgh Series Heat Pump Systems SpecificationsElectrical Specifications Heat Pump Units Pkgh Series Heat Pump SystemsStandard Operating Data PCH Indoor Units with Pugh Outdoor UnitsModels PCH24GK PCH30GK PCH36GK PCH42GK PKH Indoor Units with Pugh Outdoor Units Models PKH18FK PKH24FK PKH30FK PKH36FKPLH Indoor Units with Pugh Outdoor Units Models PLH18GK PLH24GK PLH30GK PLH36GK PLH42GKPerformance Data Operating Pressures Cooling PCH24GK+PUGH24 Indoor Air = 810 CFMPCH30GK+PUGH30 Indoor Air = 1130 CFM PCH36GK+PUGH36 Indoor Air = 1130 CFM PCH42GK+PUGH42 Indoor Air = 1130 CFM PKH18FK+PUGH18 Indoor Air = 640 CFM PKH24FK+PUGH24 Indoor Air = 640 CFM PKH30FK+PUGH30 Indoor Air = 910 CFM PKH36FK+PUGH36 Indoor Air = 885 CFM PLH18AK+PUGH18 Indoor Air = 670 CFM PLH24AK+PUGH24 Indoor Air = 950 CFM PLH30AK+PUGH30 Indoor Air = 1020 CFM PLH36AK+PUGH36 Indoor Air = 1020 CFM PLH42AK+PUGH42 Indoor Air = 1100 CFM PKH30FK/PUGH30 Performance Data Operating Pressures HeatingPKH18FK/PUGH18 PKH24FK/PUGH24PLH30AK/PUGH30 PLH18AK/PUGH18PLH24AK/PUGH24 PLH36AK/PUGH36PCH36GK/PUGH36 PCH24GK/PUGH24PCH30GK/PUGH30 PCH42GK/PUGH42Dimensions and Clearances Typical InstallationOperating Pressures / Superheat System Charge Measurement MethodSuperheat Charging Method Temperature and Pressure Operating Pressures / SuperheatOperating Temperature Range Operating RangeModel Liquid OD Vapor OD CHARGE, OZ/FT Factory Charge ADD Charge ARI Rating Point ModelCHARGE, OZ Capacity Correction Factors for Various Pipe Lengths Model Refrigerant Piping Length ONE WAYMicroprocessor Control COOLING/HEATING OperationLED Flashes Indication of Condition Electrical Service Ports Refrigerant SystemParts Breakdown Models 18, 24, Description PUGH018AYB PUGH024AYB PUGH030AYBModels 36 Description PUGH036AYB PUGH042AYBMitsubishi Electronics 036-21544-001 Specifications are subject to change without notice