Mitsubishi Electronics PUGH36AYB, PUGH42AYB, PUGH24AYB PLH24AK+PUGH24 Indoor Air = 950 CFM

Page 16

036-21544-001 Rev. B (1103)

4 PERFORMANCE DATA - OPERATING PRESSURES - COOLING

PLH24AK+PUGH24 (Indoor Air = 950 CFM)

75 °F Outdoor Air Temperature

Indoor Wet

Cooling

 

Total

Net Sensible Cooling Capacity (Btu/hr)

 

Pressures

Capacity

EER

Power

 

Indoor Dry Bulb (°F)

 

 

 

(psig)

Bulb (°F)

 

 

 

 

(Btu/hr)

 

(Watts)

 

 

 

 

 

 

 

 

 

 

70

75

80

85

90

Suction

 

Discharge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

25,376

10.56

2,402

15,758

19,875

23,553

27,230

31,347

67

 

217

 

 

 

 

 

 

 

 

 

 

 

 

65

26,820

10.95

2,449

14,279

18,395

22,105

25,814

29,930

70

 

223

 

 

 

 

 

 

 

 

 

 

 

 

67

28,264

11.34

2,493

12,799

16,916

20,656

24,397

28,514

73

 

229

 

 

 

 

 

 

 

 

 

 

 

 

69

29,709

11.72

2,534

11,319

15,436

19,208

22,981

27,098

76

 

235

 

 

 

 

 

 

 

 

 

 

 

 

71

31,153

12.11

2,572

9,839

13,956

17,760

21,565

25,681

79

 

241

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

85 °F Outdoor Air Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Wet

Cooling

 

Total

Net Sensible Cooling Capacity (Btu/hr)

 

Pressures

Capacity

EER

Power

 

Indoor Dry Bulb (°F)

 

 

 

(psig)

Bulb (°F)

 

 

 

 

(Btu/hr)

 

(Watts)

 

 

 

 

 

 

 

 

 

 

70

75

80

85

90

Suction

 

Discharge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

18,361

9.73

1,886

14,835

18,952

22,428

25,904

30,021

69

 

243

 

 

 

 

 

 

 

 

 

 

 

 

65

21,015

9.96

2,110

13,370

17,487

21,206

24,603

28,720

72

 

249

 

 

 

 

 

 

 

 

 

 

 

 

67

26,332

10.06

2,617

11,905

16,022

19,984

23,301

27,418

75

 

256

 

 

 

 

 

 

 

 

 

 

 

 

69

27,655

10.37

2,668

10,440

14,557

18,440

22,000

26,117

79

 

262

 

 

 

 

 

 

 

 

 

 

 

 

71

28,979

10.67

2,716

8,975

13,091

16,895

20,699

24,815

82

 

269

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

95 °F Outdoor Air Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Wet

Cooling

 

Total

Net Sensible Cooling Capacity (Btu/hr)

 

Pressures

Capacity

EER

Power

 

Indoor Dry Bulb (°F)

 

 

 

(psig)

Bulb (°F)

 

 

 

 

(Btu/hr)

 

(Watts)

 

 

 

 

 

 

 

 

 

 

70

75

80

85

90

Suction

 

Discharge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

11,346

8.28

1,370

13,912

18,029

21,304

24,578

28,695

72

 

269

 

 

 

 

 

 

 

 

 

 

 

 

65

15,211

8.59

1,771

12,462

16,579

20,308

23,392

27,509

75

 

275

 

 

 

 

 

 

 

 

 

 

 

 

67

24,400

8.90

2,742

11,011

15,128

19,312

22,205

26,322

78

 

282

 

 

 

 

 

 

 

 

 

 

 

 

69

25,602

9.14

2,802

9,560

13,677

17,671

21,019

25,136

81

 

289

 

 

 

 

 

 

 

 

 

 

 

 

71

26,805

9.37

2,859

8,110

12,227

16,030

19,833

23,949

84

 

296

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

105 °F Outdoor Air Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Wet

Cooling

 

Total

Net Sensible Cooling Capacity (Btu/hr)

 

Pressures

Capacity

EER

Power

 

Indoor Dry Bulb (°F)

 

 

 

(psig)

Bulb (°F)

 

 

 

 

(Btu/hr)

 

(Watts)

 

 

 

 

 

 

 

 

 

 

70

75

80

85

90

Suction

 

Discharge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

14,732

6.93

2,126

13,032

17,149

20,220

23,290

27,407

74

 

300

 

 

 

 

 

 

 

 

 

 

 

 

65

17,236

7.29

2,366

11,585

15,701

19,110

22,197

26,313

77

 

306

 

 

 

 

 

 

 

 

 

 

 

 

67

22,403

7.76

2,888

10,137

14,254

18,001

21,103

25,220

80

 

313

 

 

 

 

 

 

 

 

 

 

 

 

69

23,576

7.98

2,953

8,689

12,806

16,569

20,010

24,127

83

 

319

 

 

 

 

 

 

 

 

 

 

 

 

71

24,749

8.21

3,015

7,241

11,358

15,138

18,917

23,034

86

 

326

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

115 °F Outdoor Air Temperature

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor Wet

Cooling

 

Total

Net Sensible Cooling Capacity (Btu/hr)

 

Pressures

Capacity

EER

Power

 

Indoor Dry Bulb (°F)

 

 

 

(psig)

Bulb (°F)

 

 

 

 

(Btu/hr)

 

(Watts)

 

 

 

 

 

 

 

 

 

 

70

75

80

85

90

Suction

 

Discharge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

63

18,118

6.29

2,881

12,153

16,269

19,135

22,002

26,118

77

 

331

 

 

 

 

 

 

 

 

 

 

 

 

65

19,261

6.51

2,961

10,708

14,824

17,913

21,001

25,118

80

 

337

 

 

 

 

 

 

 

 

 

 

 

 

67

20,405

6.72

3,035

9,263

13,380

16,690

20,001

24,118

83

 

343

 

 

 

 

 

 

 

 

 

 

 

 

69

21,549

6.94

3,105

7,818

11,935

15,468

19,001

23,118

86

 

350

 

 

 

 

 

 

 

 

 

 

 

 

71

22,693

7.16

3,170

6,373

10,490

14,246

18,001

22,118

89

 

356

 

 

 

 

 

 

 

 

 

 

 

 

16

Mitsubishi Electronics 2003

Image 16
Contents Applies to Voltage Phase Suffix Pugh Outdoor UnitDescription and Features Capacity Correction Factors forSpecifications Electrical Specifications Heat Pump UnitsPcgh Series Heat Pump Systems Pkgh Series Heat Pump SystemsPCH Indoor Units with Pugh Outdoor Units Standard Operating DataModels PCH24GK PCH30GK PCH36GK PCH42GK PKH Indoor Units with Pugh Outdoor Units Models PKH18FK PKH24FK PKH30FK PKH36FKPLH Indoor Units with Pugh Outdoor Units Models PLH18GK PLH24GK PLH30GK PLH36GK PLH42GKPerformance Data Operating Pressures Cooling PCH24GK+PUGH24 Indoor Air = 810 CFMPCH30GK+PUGH30 Indoor Air = 1130 CFM PCH36GK+PUGH36 Indoor Air = 1130 CFM PCH42GK+PUGH42 Indoor Air = 1130 CFM PKH18FK+PUGH18 Indoor Air = 640 CFM PKH24FK+PUGH24 Indoor Air = 640 CFM PKH30FK+PUGH30 Indoor Air = 910 CFM PKH36FK+PUGH36 Indoor Air = 885 CFM PLH18AK+PUGH18 Indoor Air = 670 CFM PLH24AK+PUGH24 Indoor Air = 950 CFM PLH30AK+PUGH30 Indoor Air = 1020 CFM PLH36AK+PUGH36 Indoor Air = 1020 CFM PLH42AK+PUGH42 Indoor Air = 1100 CFM Performance Data Operating Pressures Heating PKH18FK/PUGH18PKH30FK/PUGH30 PKH24FK/PUGH24PLH18AK/PUGH18 PLH24AK/PUGH24PLH30AK/PUGH30 PLH36AK/PUGH36PCH24GK/PUGH24 PCH30GK/PUGH30PCH36GK/PUGH36 PCH42GK/PUGH42Dimensions and Clearances Typical InstallationMeasurement Method Operating Pressures / Superheat System ChargeSuperheat Charging Method Temperature and Pressure Operating Pressures / SuperheatOperating Temperature Range Operating RangeFactory Charge ADD Charge ARI Rating Point Model Model Liquid OD Vapor OD CHARGE, OZ/FTCHARGE, OZ Capacity Correction Factors for Various Pipe Lengths Model Refrigerant Piping Length ONE WAYMicroprocessor Control COOLING/HEATING OperationLED Flashes Indication of Condition Electrical Service Ports Refrigerant SystemParts Breakdown Models 18, 24, Description PUGH018AYB PUGH024AYB PUGH030AYBModels 36 Description PUGH036AYB PUGH042AYBMitsubishi Electronics 036-21544-001 Specifications are subject to change without notice