SPECIFICATION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

 

Model

 

MSZ-D30NA

MSY-D30NA

 

MSZ-D36NA

MSY-D36NA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

30,700

30,700

 

32,000/33,200

33,200/34,600

 

 

 

 

Cooling

1

 

Btu/h

 

 

(9,800 ~ 32,000) /

(9,800 ~ 33,200) /

Capacity

 

 

 

(9,800 ~ 30,700)

(9,800 ~ 30,700)

 

 

 

 

 

 

 

 

(9,800 ~ 33,200)

(9,800 ~ 34,600)

Rated(Minimum~Maximum)

 

 

 

 

 

 

 

 

 

 

Heating 47

1

Btu/h

 

32,600

 

35,200

 

 

 

 

 

 

 

 

 

 

 

(8,700 ~ 34,000)

 

(8,700 ~ 36,000)

 

 

 

 

 

 

 

 

 

 

 

 

Capacity Rated

Heating 17

2

Btu/h

 

20,800

 

22,800

 

 

 

 

Cooling

 

 

 

 

3,850

3,380

 

4,140/4,360

4,210/4,240

Power consumption

1

 

W

 

 

(620 ~ 4,140) /

(620 ~ 4,210) /

 

 

(620 ~ 3,850)

(620 ~ 3,380)

 

Rated(Minimum~Maximum)

 

 

 

 

 

 

 

 

(620 ~ 4,360)

(620 ~ 4,240)

(TOTAL)

 

 

 

 

 

 

 

 

 

 

 

 

Heating 47

1

W

 

3,360

 

3,840

 

 

 

 

 

(520 ~ 3,600)

 

(520 ~ 4,100)

 

 

 

 

 

 

 

 

 

 

 

 

Power consumption Rated

Heating 17

2

W

 

2,620

 

3,000

EER 1 [SEER] 3

Cooling

 

 

 

 

8.0 [14.5]

9.1 [16.0]

 

7.7/7.6

7.9/8.2

 

 

 

 

 

[14.5]

[15.1]

 

 

 

 

 

 

 

 

 

 

 

 

HSPF IV(V)

4

Heating

 

 

 

 

(8.2)

 

(8.2)

COP

 

Heating

1

 

 

 

2.84

 

2.69

Outdoor unit model

 

 

 

 

 

MUZ-D30NA

MUY-D30NA

 

MUZ-D36NA

MUY-D36NA

External finish

 

 

 

 

 

 

Munsell 3Y 7.8/1.1

 

Power supply

V , phase , Hz

 

 

208/230 , 1 , 60

 

Max. fuse size (time delay)

 

 

A

 

 

 

25

 

Min. circuit ampacity

 

 

 

A

 

 

 

21

 

Fan motor

 

 

 

 

F.L.A

 

 

0.93

 

Compressor

 

 

 

Model

 

 

TNB220FMCHT

 

 

 

 

R.L.A

 

 

 

16

 

 

 

 

 

 

 

 

L.R.A

 

 

 

20

 

Refrigerant control

 

 

 

 

 

 

Liner expansion valve

 

Sound level

1

Cooling

 

 

dB(A)

 

55

55

 

56

56

Heating

 

 

dB(A)

 

57

 

57

 

 

 

 

 

 

 

 

Defrost method

 

 

 

 

 

Reverse cycle

 

Reverse cycle

Dimensions

 

W

 

 

in.

 

 

33-

1/16

 

 

D

 

 

in.

 

 

 

13

 

 

 

 

 

H

 

 

in.

 

 

33-7/16

 

Weight

 

 

 

 

Ib.

 

141

126

 

141

126

Remote controller

 

 

 

 

 

 

Wireless

type

 

Control voltage (by built-in transformer)

 

 

12 - 24 VDC

 

Refrigerant piping

 

 

 

 

 

 

Not supplied

 

Refrigerant pipe size

Liquid

 

 

in.

 

 

3/8 (0.0315)

 

(Min. wall thickness)

Gas

 

 

in.

 

 

5/8 (0.0394)

 

Connection method

Indoor

 

 

 

 

 

Flared

 

Outdoor

 

 

 

 

 

Flared

 

 

 

 

 

 

 

 

 

 

 

Between the indoor &

Height

 

 

ft.

 

 

 

50

 

difference

 

 

 

 

 

 

outdoor units

 

 

 

 

 

 

 

 

 

 

Piping length

ft.

 

 

 

100

 

 

 

 

 

 

 

 

 

Refrigerant charge (R410A)

 

 

 

 

4 lb. 10 oz.

4 lb.

 

4 lb. 10 oz.

4 lb.

Refrigeration oil (Model)

 

 

 

 

 

NE022

 

NOTE : Test conditions are based on ARI 210/240.

 

 

 

 

 

 

1 : Rating conditions(Cooling)

— Indoor : 80 ˚FDB, 67 ˚FWB, Outdoor : 95 ˚FDB, (75 ˚FWB)Rated frequency

 

2 :

 

(Heating) — Indoor : 70 ˚FDB, 60 ˚FWB, Outdoor : 47 ˚FDB, 43 ˚FWB Rated frequency

 

 

(Heating) — Indoor : 70 ˚FDB, 60 ˚FWB, Outdoor : 17 ˚FDB, 15 ˚FWBMaximum frequency

 

4

Image 4 Contents
Outdoor Unit Page Technical Changes Part Names and FunctionsTotal HspfCOP TNB220FMCHTARI Operating RangeSeer Outlines and Dimensions Required SpaceWiring Diagram MUY-D30NA MUY-D36NA Refrigerant System Diagram LEVMAX. Refrigerant Piping Length and MAX. Height Difference Data Performance Data Cooling CapacityPerformance Curve Cooling MUZ-D30NA MUZ-D36NA MUY-D30NAMUY-D36NA HeatingCondensing Pressure Cooling 380 420 340 300 26068 100 105F Standard Operation Data MSZ-D30NA MSZ-D36NA MSY-D30NA MSY-D36NAInput correction factors Test RUN Operation How to operate fixed-frequency operation Actuator Control Outdoor FAN Motor ControlR.V. Coil Control MUZ Relation between main sensor and actuatorChange in Defrost Setting Service FunctionsPRE-HEAT Control Troubleshooting Take care of the following during servicingFailure Mode Recall Function Operational procedure Outdoor unit failure mode table LED Troubleshooting Check Table LED1 LED2MUZ BLK WHT WHT RED YLW BRNHow to check inverter/ compressor Troubleshooting FlowCheck of outdoor thermistors Check of R.V. coil MUZ-D30/36 Heating operation does not workCheck of power supply Check of outdoor fan motorCheck of compressor start failure Check of LEVHow to check miswiring and serial signal error Check of HPS Electromagnetic noise enters into TV sets or radios Test Point Diagram and Voltage Outdoor electronic control P.C. boardNoise filter P.C. board Outdoor power board CN2CN3 CN5Disassembly Instructions Removing the cabinet PhotoRemoving R.V. coil MUZ Photo 5 Inverter assemblyHPS Temperature thermistor and ambient temperature ThermistorRemoving outdoor fan motor MUZRemoving the compressor and 4-way valve Photo Removing the reactorPage Specifications subject to change without notice