Mitsubishi Electronics MSZ-GA22VA Cleaning the Catechin AIR Filter, Front panel Heat exchanger

Page 10

CLEANING THE FRONT PANEL, HEAT EXCHANGER AND FAN

CLEANING THE CATECHIN AIR FILTER

Front panel

Heat exchanger

Cleaning the catechin air filter (about once every 2 weeks)

1Hold both ends of the front panel and lift the panel up until a “click” is heard. (1) Holding the hinges, lift the panel up until it is level, and pull the hinges forward to remove the front panel. (2)

1

2

Hinge

Hole

CAUTION:

Do not drop the front panel or pull it out forcibly. The panel may be damaged.

Do not step onto an unstable bench when removing or installing the front panel.

This may cause an injury, etc. if you fall down.

2 Wipe the front panel with a soft dry cloth or

wash it with water.

After washing the panel, wipe up the remain-

ing water with a soft dry cloth and let it dry

out of direct sunlight.

• If the dirt is noticeable, wipe the front panel with a

cloth soaked in a solution of mild detergent diluted

in lukewarm water.

• Do not use gasoline, benzine, thinner, polishing

powder, or insecticide and do not wash the front

panel with a scrubbing brush or the hard surface of

a sponge.

Remove the catechin air filter before clean- ing the heat exchanger.

Heat exchanger

You can sweep the surface of heat exchanger if you install the brush of QUICK CLEAN KIT to your vacuum cleaner. Please refer to the instructions described in QUICK CLEAN KIT for details (packaged in outdoor unit).

WARNING:

Do not touch the heat exchanger directly with your hands. Otherwise you may get injured. (It’s recom- mended to protect your hands with a pair of gloves.)

CAUTION:

Do not step onto an unstable bench when cleaning. Otherwise you may fall down and get injured.

Use only the brush of QUICK CLEAN KIT. Do not use other stuffs. Otherwise the heat exchanger of the in- door unit may get damaged.

NOTE:

The QUICK CLEAN KIT can only be fitted to a vacuum cleaner with a hose/tube diameter (inside diameter) of 32 to 39 mm. Refer to the instructions of the QUICK CLEAN KIT packaged in outdoor unit for more details.

Fan

1Remove the catechin air filter.

Open the front panel, then remove/replace the filter.

Catechin air filter

Remove.

CAUTION:

When the catechin air filter is to be removed, do not touch the metal parts of the indoor unit.

This may cause an injury.

2Remove dirt from the catechin air filter us- ing a vacuum cleaner or by washing the fil- ter with water.

Do not wash with scrubbing brush or hard surface of sponge. Otherwise, the filter may deform.

If the dirt is noticeable, wash the filter with a solu- tion of mild detergent diluted in lukewarm water.

If hot water (50 °C or more) is used, the filter may be deformed.

3After washing with water/lukewarm water, dry the catechin air filter well in the shade.

Do not expose the catechin air filter to direct sun- light or heat from a fire when drying it.

4Install the catechin air filter. (Securely install its tabs.)

Install.

• Do not soak the front panel in water/lukewarm wa-

ter longer than two hours and do not expose the

panel to direct sunlight, heat, or flames when dry-

ing it. The panel may be deformed or discolored.

Refer to page 12 for cleaning the fan.

What is “Catechin air filter”?

The air filter is dyed with a natural material, catechin, that is contained in tea. The catechin air filter deodorizes odor and noxious gases such as formaldehyde, ammonia, and acetaldehyde. Moreover, it restraints the activity of the viruses adhering to the filter.

3Hold both ends of the front panel, keep the panel level, and insert the hinges into the holes on the upper part of the indoor unit until they click into place. Then, close the front panel securely and press the three po- sitions on the front panel as indicated by the arrows.

10

Image 10
Contents English Deutsch Français Nederlands Español Italiano Português Dansk Svenska Türkçe РусскийContents Safety PrecautionsIndoor unit Safety Precautions Name of Each PartFor installation Outdoor unitAuto restart function Remote controllerPreparation Before Operation Remoto controllerThen reattach the front lid Press the Reset buttonPress the Emergency Operation switch Press the Clock set buttonAuto CHANGEOVER... Auto Mode Operation Select the operation mode by pressing the Mode button AIR Flow Velocity and Direction AdjustmentTo select the COOL, DRY or Heat mode Manual Operation COOL, DRY, HeatMovement of the horizontal vane Air blows out upper than positionMaintenance Timer Operation ON/OFF TimerEcono Cool Operation Front panel Heat exchanger Cleaning the Catechin AIR FilterCleaning the catechin air filter about once every 2 weeks FanCleaning the air cleaning filter about once every 3 months Air cleaning filter replacement about once every yearCleaning Cleaning the AIR Outlet and FAN of the Indoor UnitBefore cleaning After CleaningWhen YOU Think That Trouble has Occurred INSTALLATION, Relocation and Inspection SpecificationsSG79Y402H01
Related manuals
Manual 32 pages 50.33 Kb

MSZ-GA25VA, MSZ-GA35VA, MSZ-GA22VA specifications

The Mitsubishi Electronics MSZ-GA series encompasses a range of wall-mounted split systems, including the MSZ-GA22VA, MSZ-GA25VA, and MSZ-GA35VA models, designed to provide efficient heating and cooling solutions for a variety of environments. Renowned for their advanced technology and user-friendly features, these air conditioning units are a perfect match for residential and light commercial spaces.

One of the standout features of the MSZ-GA series is the innovative INVERTER technology. This system intelligently adjusts the compressor speed, ensuring that the units operate at optimal efficiency. By maintaining a consistent temperature without constant on/off cycling, this technology significantly reduces energy consumption, leading to lower electricity bills and a reduced carbon footprint.

Another major aspect of these models is their powerful yet quiet operation. The units are designed with advanced noise-reduction technology, allowing them to function at low sound levels, making them ideal for bedrooms and living rooms where disturbances should be kept to a minimum. With noise levels as low as 19 dB(A), users can enjoy a peaceful indoor environment even while the system is running.

Additionally, the MSZ-GA22VA, MSZ-GA25VA, and MSZ-GA35VA models feature an elegant and compact design, which easily integrates into any interior decor. Their sleek and minimalist aesthetics do not compromise on performance, making them a favorite among homeowners and designers alike.

The series also comes with a user-friendly remote control, enabling easy temperature adjustments and settings from across the room. For added convenience, these models include a programmable timer feature, allowing users to set the system to operate according to their schedules. This flexibility not only enhances comfort but also optimizes energy usage.

Moreover, the MSZ-GA series incorporates a powerful air filtration system that helps improve indoor air quality. Featuring a washable anti-allergy enzyme filter, these units capture dust and allergens, making the air cleaner and healthier for occupants.

With a focus on energy efficiency, quiet operation, and advanced air purification, the Mitsubishi Electronics MSZ-GA22VA, MSZ-GA25VA, and MSZ-GA35VA represent an excellent choice for anyone seeking reliable and effective climate control solutions. Whether heating or cooling, these models ensure maximum comfort while minimizing energy usage and environmental impact.