Mitsubishi Electronics MSZ-GA35VA, MSZ-GA25VA Then reattach the front lid, Press the Reset button

Page 5

PREPARATION BEFORE OPERATION

Remote controller

How to set the batteries and the current time

1 Remove the front lid and insert batteries.

Handling of the remote controller

The range that the signal can reach is about 6 m when

 

the remote controller is pointed at the front of the in-

 

door unit.

When a button is pressed, one or two beeps will be

When the remote controller cannot be used (emergency operation)

When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the EMERGENCY OPERATION switch.

Then reattach the front lid.

Insert the minus pole of the batteries first.

Check if the polarity of the batteries is correct.

Insert the minus pole of the batteries first.

2Press the RESET button.

Press using a thin stick.

If the RESET button is not pressed, the remote con- troller may not operate correctly.

Be sure to press the RESET button not too strongly.

3Press the CLOCK set button.

Press using a thin stick.

heard from the indoor unit. If no sound is heard, op-

erate again.

• Use the remote controller carefully.

If it is dropped, thrown or it gets wet, the remote con-

troller may not operate.

When installing on a wall, etc.

Install the remote controller holder in a position where the signal reception sound (beep) can be heard from the indoor unit when the ON/OFF button is pressed.

How to install/remove the remote controller

Installing :Insert the remote controller downward. Removing :Pull it up.

Remote controller holder

Dry-cell batteries

Reference for replacing batteries

Replace the batteries with new AAA alkaline batteries in the following cases:

·When the indoor unit does not respond to the remote control signal.

·When the display on the remote controller becomes dim.

·When a button of the remote controller is pressed, all displays appear on the screen, and then disappear

immediately.

Do not use manganese batteries. The remote controller

1Press the EMERGENCY OPERATION switch.

Each time the EMERGENCY OPERATION switch is pressed, the unit will operate in order of EMER-

GENCY COOL MODE, EMERGENCY HEAT MODE and STOP MODE.

However, when the EMERGENCY OPERATION switch is once pressed, the unit will operate in test run for 30 minutes and then the operation mode shifts to EMERGENCY MODE.

Details of EMERGENCY MODE are as shown be- low. However, the temperature control does not work for 30 minutes in test run and the unit is set to continuous operation. The fan speed is set to High in test run and shifts to Medium after 30 min- utes.

Operation mode

COOL

HEAT

Set temperature

24°C

24°C

 

 

 

Fan speed

Medium

Medium

 

 

 

Horizontal vane

Auto

Auto

 

 

 

2To stop the emergency operation, press the EMERGENCY OPERATION switch once (in case of EMERGENCY HEAT MODE) or twice (in case of EMERGENCY COOL MODE).

4Press the (Forward) and (Back- ward) buttons (TIME SET buttons) to set the

current time.

Each time the button is pressed, the set time

increases by 1 minute, and each time the but- ton is pressed, the set time decreases by 1 minute.

Pressing those buttons longer increases/decreases the set time by 10 minutes.

5Press the CLOCK set button again and close the front lid.

could malfunction.

The service life of an alkaline battery is about 1 year. However, a battery whose time limit is approaching may be exhausted soon. The recommended usable time limit is indicated (month/year) on the bottom of the battery.

To prevent liquid leakage, take out all batteries when the remote controller is not going to be used for a long time.

CAUTION:

If liquid from the batteries gets onto your skin or clothes, wash it well with clean water.

If liquid from the batteries gets into your eyes, wash them well with clean water and consult a doctor at once.

Do not use rechargeable batteries.

Replace the 2 batteries with new ones of the same type.

Dispose of exhausted batteries in the correct man- ner.

The operation mode is indicated by the Operation Indicator lamp on the indoor unit as following fig- ure.

Operation Indicator lamp

EMERGENCY COOL

EMERGENCY HEAT

STOP

5

Image 5
Contents Português Dansk Svenska Türkçe Русский English Deutsch Français Nederlands Español ItalianoSafety Precautions ContentsFor installation Safety Precautions Name of Each PartIndoor unit Outdoor unitPreparation Before Operation Remote controllerAuto restart function Remoto controllerPress the Emergency Operation switch Press the Reset buttonThen reattach the front lid Press the Clock set buttonAuto CHANGEOVER... Auto Mode Operation To select the COOL, DRY or Heat mode AIR Flow Velocity and Direction AdjustmentSelect the operation mode by pressing the Mode button Manual Operation COOL, DRY, HeatAir blows out upper than position Movement of the horizontal vaneEcono Cool Operation Timer Operation ON/OFF TimerMaintenance Cleaning the catechin air filter about once every 2 weeks Cleaning the Catechin AIR FilterFront panel Heat exchanger FanAir cleaning filter replacement about once every year Cleaning the air cleaning filter about once every 3 monthsBefore cleaning Cleaning the AIR Outlet and FAN of the Indoor UnitCleaning After CleaningWhen YOU Think That Trouble has Occurred Specifications INSTALLATION, Relocation and InspectionSG79Y402H01
Related manuals
Manual 32 pages 50.33 Kb

MSZ-GA25VA, MSZ-GA35VA, MSZ-GA22VA specifications

The Mitsubishi Electronics MSZ-GA series encompasses a range of wall-mounted split systems, including the MSZ-GA22VA, MSZ-GA25VA, and MSZ-GA35VA models, designed to provide efficient heating and cooling solutions for a variety of environments. Renowned for their advanced technology and user-friendly features, these air conditioning units are a perfect match for residential and light commercial spaces.

One of the standout features of the MSZ-GA series is the innovative INVERTER technology. This system intelligently adjusts the compressor speed, ensuring that the units operate at optimal efficiency. By maintaining a consistent temperature without constant on/off cycling, this technology significantly reduces energy consumption, leading to lower electricity bills and a reduced carbon footprint.

Another major aspect of these models is their powerful yet quiet operation. The units are designed with advanced noise-reduction technology, allowing them to function at low sound levels, making them ideal for bedrooms and living rooms where disturbances should be kept to a minimum. With noise levels as low as 19 dB(A), users can enjoy a peaceful indoor environment even while the system is running.

Additionally, the MSZ-GA22VA, MSZ-GA25VA, and MSZ-GA35VA models feature an elegant and compact design, which easily integrates into any interior decor. Their sleek and minimalist aesthetics do not compromise on performance, making them a favorite among homeowners and designers alike.

The series also comes with a user-friendly remote control, enabling easy temperature adjustments and settings from across the room. For added convenience, these models include a programmable timer feature, allowing users to set the system to operate according to their schedules. This flexibility not only enhances comfort but also optimizes energy usage.

Moreover, the MSZ-GA series incorporates a powerful air filtration system that helps improve indoor air quality. Featuring a washable anti-allergy enzyme filter, these units capture dust and allergens, making the air cleaner and healthier for occupants.

With a focus on energy efficiency, quiet operation, and advanced air purification, the Mitsubishi Electronics MSZ-GA22VA, MSZ-GA25VA, and MSZ-GA35VA represent an excellent choice for anyone seeking reliable and effective climate control solutions. Whether heating or cooling, these models ensure maximum comfort while minimizing energy usage and environmental impact.