3-1. OPERATING RANGE
(1) POWER SUPPLY
| Rated voltage |
| Guaranteed Voltage | |||
|
|
|
|
|
|
|
| 208/230 V | Min.187 V 208 V 230 V Max.253 V | ||||
Indoor unit | 1 phase |
|
|
|
|
|
|
|
|
|
| ||
| 60 Hz |
|
|
|
|
|
|
|
|
|
|
|
|
(2) OPERATION
Mode | Condition |
|
| Intake air temperature (°F) |
|
| |
Indoor |
|
| Outdoor | ||||
|
| DB |
| WB | DB |
| WB |
| Standard temperature | 80 |
| 67 | 95 |
| — |
Cooling | Maximum temperature | 90 |
| 73 | 115 |
| — |
Minimum temperature | 67 |
| 57 | 14 |
| — | |
|
|
| |||||
| Maximum humidity | 78 | % |
|
| — | |
Heating | Standard temperature | 70 |
| 60 | 47 |
| 43 |
Maximum temperature | 80 |
| 67 | 75 |
| 65 | |
| Minimum temperature | 70 |
| 60 | 14 |
| 13 |
3-2. OUTLET AIR SPEED AND COVERAGE RANGE
Model | Mode | Function | Airflow | Air speed | Coverage | |
(CFM) | (ft./sec.) | range (ft.) | ||||
|
|
| ||||
| HEAT | Dry | 381 | 19.2 | 27.7 | |
COOL | Dry | 339 | 17.1 | 24.7 | ||
| Wet | 307 | 15.5 | 22.4 | ||
|
| |||||
| HEAT | Dry | 420 | 21.2 | 30.4 | |
COOL | Dry | 381 | 19.2 | 27.7 | ||
| Wet | 350 | 17.6 | 25.4 | ||
|
|
●The air coverage range is the figure up to the position where the air speed is 1 ft./sec., when air is blown out horizon- tally from the unit properly at the High speed position.
The coverage range should be used only as a general guideline since it var- ies according to the size of the room and furniture arranged inside the room.
6