Installation Instructions

WORKSHEET—CALCULATE TOTAL EQUIVALENT DUCTWORK LENGTH

DUCT

EQUIVALENT NUMBER

 

 

PIECES

LENGTH

x USED

=

TOTAL

31⁄4″ x 10″

1 Ft.

x

(

)

=

Ft.

Rect.,

 

 

 

 

 

 

straight

 

 

 

 

 

 

7″ Round,

1 Ft.

x

(

)

=

Ft.

straight

 

 

 

 

 

 

6″ Round,

1 Ft.

x

(

)

=

Ft.

straight

 

 

 

 

 

 

31⁄4″ x 10″

14 Ft.

x

(

)

=

Ft.

Rect. 90°

 

 

 

 

 

 

elbow

 

 

 

 

 

 

31⁄4″ x 10″

8 Ft.

x

(

)

=

Ft.

Rect. 45°

 

 

 

 

 

 

elbow

 

 

 

 

 

 

31⁄4″ x 10″

33 Ft.

x

(

)

=

Ft.

Rect. 90°

 

 

 

 

 

 

flat elbow

 

 

 

 

 

 

31⁄4″ x 10″

24 Ft.

x

(

)

=

Ft.

Rect.

(18 ft. w/o

 

 

 

 

 

wall cap

damper)

x

(

)

=

Ft.

with

 

 

 

 

 

 

damper

 

 

 

 

 

 

31⁄4″ x 10″

2 Ft.

x

(

)

=

Ft.

Rect. to

 

 

 

 

 

 

6″ round

 

 

 

 

 

 

transition

 

 

 

 

 

 

31⁄4″ x 10″

4 Ft.

x

(

)

=

Ft.

Rect. to

 

 

 

 

 

 

6″ round

 

 

 

 

 

 

transition

 

 

 

 

 

 

90° elbow

 

 

 

 

 

 

6″ Round,

25 Ft.

x

(

)

=

Ft.

90° elbow

 

 

 

 

 

 

6″ Round,

16 Ft.

x

(

)

=

Ft.

45° elbow

 

 

 

 

 

 

 

Subtotal column 1

 

=

Ft.

MAXIMUM DUCT LENGTH: For satisfactory air movement, the total duct length of a 31⁄ 4″ x 10″ rectangular, 7″ diameter round duct should not exceed 65 equivalent feet.

DUCT

EQUIVALENT

 

NUMBER

 

 

PIECES

LENGTH

x USED

=

TOTAL

6″ Round

53 Ft.

x

(

)

=

Ft.

wall cap

(39 ft. w/o

 

 

 

 

 

with

damper)

x

(

)

=

Ft.

damper

 

 

 

 

 

 

6″ Round

72 Ft.

x

(

)

=

Ft.

roof cap

 

 

 

 

 

 

6″ Round

3 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

31⁄4″ x 10″

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition

 

 

 

 

 

 

6″ Round

9 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

31⁄4″ x 10″

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition

 

 

 

 

 

 

90° elbow

 

 

 

 

 

 

7″ Round,

14 Ft.

x

(

)

=

Ft.

90° elbow

 

 

 

 

 

 

7″ Round,

9 Ft.

x

(

)

=

Ft.

45° elbow

 

 

 

 

 

 

7″ Round

28 Ft.

x

(

)

=

Ft.

wall cap

(21 ft. w/o

 

 

 

 

 

with

damper)

x

(

)

=

Ft.

damper

 

 

 

 

 

 

7″ Round

39 Ft.

x

(

)

=

Ft.

roof cap

 

 

 

 

 

 

7″ Round

1 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

31⁄4″ x 10″

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition

 

 

 

 

 

 

7″ Round

5 Ft.

x

(

)

=

Ft.

to

 

 

 

 

 

 

31⁄4″ x 10″

 

 

 

 

 

 

rect.

 

 

 

 

 

 

transition,

 

 

 

 

 

 

90° elbow

 

 

 

 

 

 

 

Subtotal column 2

 

=

Ft.

 

Subtotal column 1

 

=

Ft.

Total ductwork

=

Ft.

7

Image 7
Contents You can find them on a label on the back wall of the hood Range HoodsUse an extinguisher only if This unit must be groundedDucted fans must always be vented to the outdoors Cet appareil doit être bien mis à la terre Le fabricant’UTILISEZ UN Extincteur que si Turn to on while cooking or to Nite for use as Night light That create a frequent need for cleaningPress the pad at the top to turn the light on Continuous use of the fan system while cookingLift the light cover and slide it toward you in one motion Remove the bulb and replace it withElbows, transitions, wall and roofcaps, etc Ductwork RequirementsExhaust connection Maximum duct lengthWORKSHEET-CALCULATE Total Equivalent Ductwork Length Installation InstructionsParts Included Damage SHIPMENT/INSTALLATIONMounting Space Tools YOU will NeedRecirculating Choose Vent OptionOutside top exhaust Outside rear exhaustRemove Filter Remove Wiring CoverRemove Wiring Knockout Remove Exhaust AdaptorFor RECESSED-BOTTOM Cabinets Only For 7″ Round Vertical Ducted Discharge Installations onlyFor 31⁄4″ X 10″ Rectangular OnlyMark Holes RUN WiresCUT Holes Secure Hood Optional Power Cord KIT JXHC1Feed in Wires Screw in Part WAYTroubleshooting Checklist Install Light BulbConnect Wiring Replace Wiring CoverGE Range Hood Warranty By phone at 800.626.2002 during normal business hours Schedule Service