GE Comprehensive Guide to Installing 327 Bulb Compatible Ventilation Hoods

Page 8

Installation Instructions

DAMAGE – SHIPMENT/INSTALLATION

If the unit is damaged in shipment, return the unit to the store in which it was bought for repair or replacement.

If the unit is damaged by the customer, repair or replacement is the responsibility of the customer.

If the unit is damaged by the installer (if other than the customer), repair or replacement must be made by arrangement between customer and installer.

MOUNTING SPACE

Bottom edge of

 

cabinet needs

 

to be 30or

 

more from

 

the cooking

 

surface

30or 36

30

 

min.

66or more from the floor to the top of the hood

NOTES:

This range hood is for installation over ranges or cooktops up to 36wide.

If you are going to vent your range hood to the outside, see the “Ducting Requirements” section for exhaust duct

preparation.

TOOLS YOU WILL NEED

 

Flat-blade and Phillips

Pencil

 

screwdrivers

 

Duct tape

Saw (saber or keyhole)

Electric drill

Metal snips

 

 

 

(in some

 

 

 

applications)

1/4pivoting

Pliers

Tape measure

Wire stripper

hex socket

 

 

 

Flashlight

Caulking

Level

1/4Nutdriver

PARTS INCLUDED

PART

QUANTITY

Grease Filter only (JV338)

1

Charcoal Filter only

1

(JN327 and RN328)

 

Grease Filter and Charcoal

2

Filter (JV347, JV348 and JV367)

 

Mounting Screws

4

(8 - 18x 3/4Phillips pan head)

 

Exhaust Adaptor

1

(for 314x 10rect. venting)

 

Exhaust Adaptor Screw

1

(8 - 18x 3/8Phillips pan head

 

or hex head)

 

8

Image 8
Contents Range Hoods You can find them on a label on the back wall of the hoodDucted fans must always be vented to the outdoors This unit must be groundedUse an extinguisher only if ’UTILISEZ UN Extincteur que si Le fabricantCet appareil doit être bien mis à la terre Night light That create a frequent need for cleaning Press the pad at the top to turn the light onContinuous use of the fan system while cooking Turn to on while cooking or to Nite for use asRemove the bulb and replace it with Lift the light cover and slide it toward you in one motionDuctwork Requirements Exhaust connectionMaximum duct length Elbows, transitions, wall and roofcaps, etcInstallation Instructions WORKSHEET-CALCULATE Total Equivalent Ductwork LengthDamage SHIPMENT/INSTALLATION Mounting SpaceTools YOU will Need Parts IncludedChoose Vent Option Outside top exhaustOutside rear exhaust RecirculatingRemove Wiring Cover Remove Wiring KnockoutRemove Exhaust Adaptor Remove FilterFor 7″ Round Vertical Ducted Discharge Installations only For 31⁄4″ X 10″ RectangularOnly For RECESSED-BOTTOM Cabinets OnlyCUT Holes RUN WiresMark Holes Optional Power Cord KIT JXHC1 Feed in WiresScrew in Part WAY Secure HoodInstall Light Bulb Connect WiringReplace Wiring Cover Troubleshooting ChecklistGE Range Hood Warranty Schedule Service By phone at 800.626.2002 during normal business hours