Honeywell PCR-300 RC manual Terminal Description, Instructions

Page 7

Terminal:

Description:

1

- 2

T1

= Cold store sensor

3

- 4

T2

= Evaporator sensor

10 - 12

Mains

= Power supply

13 - 15

V

= Compressor contactor (cooling)

17 - 18

Ev

= Evaporator fan (contactor)

20

- 21

Alarm = Remote alarm indicator; indicator lamp or

 

 

 

contactor (with RC-element)

23

- 24

Def

= Defrost heating

 

 

 

(contactor) or hot gas valve

The unit is equipped with an opto-decoupled electronic alarm output.

Take note of the alarm output limit values.

ISupply voltage: Max. 250 V AC.

IMinimum load: 40 mA

IMaximum load: 80 mA

IIf an inductive load (contactor or horn) is connected, connect an RC element directly at its coil.

Instructions:

IPay attention to the contact loading of the relay

(8A / 5A resistive load, 2A / 1A inductive load). As a general rule, contactors are recommended.

IThe maximum tested sensor cable length is 50 m, with a minimum cross section of 2 x 0.75 mm2. Solder the extension cable to the sensor cable to prevent contact resistances.

IIt is advisable to use shielded sensor extension cables.

All shields must be routed at the side of the controller to one earth/protective potential. The extension cable shield must not be connected on the sensor side, otherwise bonding currents may occur via the shielding.

IThe controllers are designed respecting the highest degree of immunity to interference. If the local interference level exceeds the immunity data might get lost (AL1 in display) and the controller switches to the preprogrammed setting values. This is not a mulfunction of the controller. In such cases the means to suppress interference have to be improved (RC-elements, shielded lines).

7

Image 7
Contents PCR-300 PCR-300 RC Installation and Operating Instructions Table of Contents Use for the purpose intended Unpacking the unit and conditions of useSources of danger FunctionSafety precautions Mounting of sensor Housing with 2 mounting tabsHousings with 1 mounting tab Electrical installationInstructions Terminal DescriptionFor PCR-300 RC only Activation of the back-up batteryOperation of the controller Switching on the operating voltageKey functions Temperature Clear alarmTemperature Value for excess Temperature alarmE00 Access the second programming level by pressingSetting the cold store temperature Input parameters and input rangesE2’2 Setting the time PCR-300RC onlyExiting programming mode Press the key several times PCR-300RC only E2’1Manual defrosting Access to the second programming levelE06 Important The times must be entered Ascending order E03E04 E05E17 To exit from the programming modeE15 E16Display Meaning MaintenanceClearing alarm Warranty conditionsFault Cause Remedy Only operate the unit in dry places PTCDr. Osthues + D / Production Manager EC Declaration of ConformityAutomation and Control Solutions

PCR-300 RC, PCR-300 specifications

The Honeywell PCR-300 and PCR-300 RC are advanced portable radiation detectors designed to meet the needs of various industries, including emergency response, nuclear power plants, and environmental monitoring. Known for their reliability and accuracy, these devices are essential in a world where radiation monitoring is increasingly crucial for safety and regulatory compliance.

The PCR-300 features a compact and lightweight design, making it easily transportable. This portability does not compromise its robust construction and ability to withstand harsh environmental conditions. With an intuitive user interface, the device allows users to operate it effectively even with minimal training.

One of the standout features of the PCR-300 is its dual-range detection capability. It can accurately measure gamma radiation levels across a wide spectrum, providing real-time data to users. The instrument is equipped with a scintillation detector, which enhances its radiation sensitivity, allowing for the detection of low levels of radiation that other devices might miss.

Additionally, the PCR-300 RC model includes advanced communication capabilities, which enable users to transmit data wirelessly. This feature is particularly beneficial for teams in the field, as it allows for instant data sharing and collaboration, enhancing situational awareness during critical missions.

Another notable technology incorporated into the PCR-300 series is its built-in GPS function. This feature facilitates the tracking of radiation readings along with geographical locations, providing crucial context during surveying or emergency response. The device is designed to store measurement data, allowing for easy retrieval and analysis after the mission is complete.

Durability is also a focus in the design of the PCR-300. The device is built to resist water and dust ingress, adhering to high IP (Ingress Protection) ratings. This ensures that the device can operate effectively in various environmental conditions without fear of damage.

Battery life is another important aspect of the PCR-300, with an extended operational time that allows users to conduct lengthy assessments without frequent recharging. The intuitive display screen provides clear visual feedback, showing real-time radiation levels, battery status, and operational alerts.

In summary, the Honeywell PCR-300 and PCR-300 RC are sophisticated tools equipped with cutting-edge technology. Their combination of portability, dual-range detection, GPS functionality, and advanced communication features make them indispensable for professionals tasked with monitoring radiation in diverse settings. With a focus on durability and extended battery life, these devices ensure that safety and efficiency are always prioritized in radiation detection efforts.