Instruction Sheet

PN 51A-Xmt-P-FF-FI/rev.A

Model Solu Comp® Xmt-P-FF/FI

January 2006

FOUNDATION® Fieldbus Two-Wire pH/ORP Transmitter

For additional information, please refer to the Instruction Manuals CD shipped with this product, or visit our website at www.emersonprocess.com/raihome/liquid/.

ESSENTIAL INSTRUCTIONS

READ THIS PAGE BEFORE PROCEEDING!

Your purchase from Rosemount Analytical, Inc. has resulted in one of the finest instruments available for your particular application. These instruments have been designed, and tested to meet many national and interna- tional standards. Experience indicates that its performance is directly related to the quality of the installation and knowledge of the user in operating and maintaining the instrument. To ensure their continued operation to the design specifications, personnel should read this manual thoroughly before proceeding with installation, commissioning, operation, and maintenance of this instrument. If this equipment is used in a manner not speci- fied by the manufacturer, the protection provided by it against hazards may be impaired.

Failure to follow the proper instructions may cause any one of the following situations to occur: Loss of life; personal injury; property damage; damage to this instrument; and warranty invalidation.

Ensure that you have received the correct model and options from your purchase order. Verify that this man- ual covers your model and options. If not, call 1-800-854-8257 or 949-757-8500 to request correct manual.

For clarification of instructions, contact your Rosemount representative.

Follow all warnings, cautions, and instructions marked on and supplied with the product.

Use only qualified personnel to install, operate, update, program and maintain the product.

Educate your personnel in the proper installation, operation, and maintenance of the product.

Install equipment as specified in the Installation section of this manual. Follow appropriate local and national codes. Only connect the product to electrical and pressure sources specified in this manual.

Use only factory documented components for repair. Tampering or unauthorized substitution of parts and procedures can affect the performance and cause unsafe operation of your process.

All equipment doors must be closed and protective covers must be in place unless qualified personnel are performing maintenance.

If this equipment is used in a manner not specified by the manufacturer, the protection provided by it against hazards may be impaired.

Image 1
Contents Foundation Fieldbus Two-Wire pH/ORP Transmitter Weight/Shipping Weight 2 lb/3 lb 1 kg/1.5 kg DimensionsPH Range 0 to Digital CommunicationsPH/ORP Sensor Sensor Compatibility ChartQuick Start Guide Unpacking and Inspection Panel Mounting Panel Mount InstallationPipe Mounting Pipe Mount InstallationSurface Mounting Surface Mount InstallationLoop Power and Sensor Wiring Panel Mount Loop Power and Sensor Wiring Pipe/Surface Mount Main Menu Specifications subject to change without notice

XMT-P-FF/FI specifications

The Emerson XMT-P-FF/FI is an advanced control system designed for process automation and monitoring, particularly in the oil and gas, chemical, and water treatment industries. With its robust set of features and cutting-edge technologies, the XMT-P-FF/FI offers a reliable solution for ensuring the optimal performance of various processes.

One of the main features of the XMT-P-FF/FI is its flexibility. This system can be configured to meet the specific requirements of a wide range of applications. It supports both flow and level measurement, and thanks to its modular design, users can easily expand and adapt the system to include additional functionalities as needed. This versatility allows operators to optimize their control strategies to improve efficiency and reduce costs.

The XMT-P-FF/FI incorporates advanced technologies that enhance its performance and reliability. Its intelligent algorithms facilitate real-time data processing, enabling users to make informed decisions based on accurate, up-to-date information. The system is equipped with multiple communication options, including Ethernet, Modbus, and other industry-standard protocols, ensuring seamless integration with existing systems and devices.

This control system is also designed with a focus on ease of use. Its intuitive interface allows operators to monitor and control processes with minimal training. Users can access system diagnostics, alarm management, and historical data directly from the interface, which aids in troubleshooting and overall system optimization.

Furthermore, the XMT-P-FF/FI is built to withstand harsh environmental conditions, making it suitable for deployment in challenging industrial settings. Its rugged construction ensures durability and longevity, reducing maintenance needs and overall operational costs.

Another notable characteristic is its commitment to safety and compliance. The XMT-P-FF/FI adheres to relevant industry regulations and standards, ensuring that operations remain safe and environmentally responsible. It can also support various safety functions, further enhancing process reliability.

In summary, the Emerson XMT-P-FF/FI is a powerful and flexible solution for process automation. With advanced technologies, user-friendly features, and a strong focus on safety and reliability, it stands out as a capable control system for various industrial applications, enhancing productivity and operational efficiency.