Make sure that the cooker hood is disconnected from the power supply before carrying out the installation.

The cooker hood comes with fixing plugs which are suitable for use with most walls/ceilings. Nevertheless, you should ask a qualified technician to assess the suitability of the materials in accordance with the type of wall/ceiling. The wall/ ceiling must be sufficiently sturdy so as to support the weight of the cooker hood.

Remove the perimeter air suction panels and the grease filters.

Before installing the product:

The perforated frame for the cooker hood is supplied prior to installation in parts. The main parts making up the perforated frame are as follows:

the upper perforated frame A (x1)

the perforated frame extension brackets B (x4)

the reinforcement brackets C (x3), of which:

2 are for use on the upper part C1 - 1 of which is pre-assembled 1 is for use on the lower part C2

Description of the upper perforated frame A:

Point at which the perforated frame is fixed/hooked to the ceiling

Fixing points for extension brackets B

Fixing points for the 2 reinforcement brackets C1

Reinforcement brackets C1

Image 19
Contents EFA 9673 Page Good luck Contents For the user Safety warningsElectric cookers 500 mm Gas cookers 650 mm For the installerDescription of the Appliance Recirculation modeCoupling ring Control Panel Display Mains switch, ON/OFFModel EFA Start and choice of motor speedCharcoal filter LED C Grease and charcoal filter maintenance indicatorResetting the saturation indicator Grease filter LED FMaintenance and Care Dishwasher Metal grease filterRemoving the metal grease filter Hand washingFitting Charcoal filter20W max Cleaning the hood Charcoal filter Type Remote control RM Special accessories Something Not Working Technical Details InstallationDimensions in cm Maximum absorbed power 350 WElectrical connection GB not for UK Electrical connection for UK onlyDescription of the upper perforated frame a Before installing the productDescription of the extension brackets B Description of the reinforcement brackets C1 and C2Preparing the structural support Mm= LBetween 690 mm and 795 mm fit both C1 brackets Electrolux installation Installing the structural support to the ceiling For the filter version, the upper Installing the fluesElectrolux installation Only for EFA