Electrolux EHG 672, EHG675, EHG674 manual Important safety requirements, Location

Page 12

Important safety requirements

This hob must be installed in accordance with the Gas Safety (Installation and Use) Regulations (Current Edition) and the IEE Wiring Regulations (Current Edition).

Detailed recommendations are contained in the following British Standards Codes Of Practice: B.S. 6172/ B.S. 5440, Par. 2 and B.S. 6891 Current Editions.

The hob should not be installed in a bed sitting room with a volume of less than 20 m3. If it is installed in a room of volume less than 5 m3 an air vent of effective area of 110 cm2 is required. If it is installed in a room of volume between 5 m3 and 10 m3 an air vent of effective area of 50 cm2 is required, while if the volume exceeds 11 m3 no air is required.

However, if the room has a door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3.

If there are other fuel burning appliances in the same room, B.S. 5440 Part 2 Current Edition, should be consulted to determine the requisite air vent requirements.

Location

The hob may be located in a kitchen, a kitchen/diner or bed sitting room, but not in a bathroom or shower room.

Before making the cut out in the worktop ensure that there is a minimum distance of 55 mm. between the rear edge of the hob and the wall.

A minimum distance of 100 mm. must be left between the side edges of the hob and any adjacent cabinets or walls.

The minimum distance combustible material can be fitted above the hob in line with the edges of the hob is 420 mm. If it is fitted below 420 mm. a space of 50

mm.must be allowed from the edges of the hob. The minimum distance combustible material can be fitted directly above the hob is 700 mm.

INSTALLATION GUIDANCE INSTRUCTIONS

CLEARANCES REQUIRED

WHEN FITTING THE GAS HOB

WITHOUT A COOKER HOOD ABOVE

700 mm

 

 

 

 

420 mm

 

 

 

 

 

mm

 

 

50

 

55

 

 

mm

 

420 mm

 

 

 

 

 

 

 

100

mm

 

 

 

 

 

 

 

 

 

 

50

mm

 

 

 

 

INSTALLATION GUIDANCE INSTRUCTIONS

CLEARANCES REQUIRED

WHEN FITTING THE GAS HOB

WITH A COOKER HOOD ABOVE

600 mm

700 mm

 

420 mm

 

 

 

 

 

mm

 

 

50

 

55

 

 

mm

 

420 mm

 

 

 

100

mm

 

 

 

 

 

 

 

 

 

 

50

mm

 

 

 

 

FO 0812

FO 0813

13

Image 12
Contents Instruction Booklet Important Safety Information Child SafetyService During UseContents Installation When the HOB is First InstalledDescription of the Hob EHG Hob TopOperation HOB BurnersBurner Minimum Maximum DiameterMaintenance and Cleaning HobTopPan Supports BurnersService and Spare Parts Symptom SolutionSomething Not Working? Customer CareGuarantee Conditions Electrolux Standard Guarantee ConditionsExclusions This guarantee does not cover European GuaranteeChannel Islands ScotlandNorthern Ireland WalesMidlands London & East AngliaSouth East South WestInstructions for the Installer Engineer technical dataOverall Dimensions CUT OUT DimensionsImportant safety requirements LocationInstallation Gas ConnectionCut Out Size Rectangular cut-out size for hobBuilding Building over a kitchen unit with doorFitting the hob to the worktop Electrical connections This HOB Must be EarthedWiring diagram Ignitor Switch Ignitor UnitFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Procedure Pressure TestingCommissioning To Adjust the GAS Rate Servicing