Ignition System / Gas Ignition

Ignitor does not spark

NO

YES

Check gas supply at burner

Check plug top fuse and replace if necessary

Check polarity and earth continuity of supply point

Check earth continuity of appliance

Check continuity from 'N' on the mains connector block and "O" on the ignitor unit

Check continuity from 'L' on the mains connector block and the taps ignition switches

Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit

Check for breaks in the insulation of the HT leads

Light burner manually

Check by pass simmer adjusted

Check position of the electrode

Check fitting of burners

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Check continuity from ignition

 

 

 

Change the ignitor unit

 

switches connector to ignitor unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

Image 18
Contents Instruction Booklet Service Important Safety InformationChild Safety During UseContents Description of the Hob InstallationWhen the HOB is First Installed EHG Hob TopBurner Minimum Maximum OperationHOB Burners DiameterPan Supports Maintenance and CleaningHobTop BurnersSomething Not Working? Service and Spare PartsSymptom Solution Customer CareExclusions This guarantee does not cover Guarantee ConditionsElectrolux Standard Guarantee Conditions European GuaranteeNorthern Ireland Channel IslandsScotland WalesSouth East MidlandsLondon & East Anglia South WestOverall Dimensions Instructions for the InstallerEngineer technical data CUT OUT DimensionsImportant safety requirements LocationCut Out Size InstallationGas Connection Rectangular cut-out size for hobBuilding Building over a kitchen unit with doorFitting the hob to the worktop Electrical connections This HOB Must be EarthedWiring diagram Ignitor Switch Ignitor UnitFault Finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Procedure Pressure TestingCommissioning To Adjust the GAS Rate Servicing