Electrolux EHG674 Instructions for the Installer, Engineer technical data, Overall Dimensions

Page 11

Instructions for the Installer

Engineer technical data

OVERALL DIMENSIONS

Width:

580 mm.

Depth:

500 mm.

Height:

88 mm.

Weight:

8 Kg.

CUT OUT DIMENSIONS

Width:

550 mm.

Depth:

470 mm.

Thickness:

30 mm.

SUPPLY CONNECTIONS

Gas:

RC 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230-240V 50Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

This appliance complies with the EEC Directive No 89/336, concerning suppression of radio electrical interference.

Ignition HT Spark

 

 

 

 

 

 

 

 

 

 

 

 

Spark Generator

 

Ispra Control's BF 50046 - 230-240V

0.6 YA T 120

Spark Gap

 

 

Fixed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Rear Left Burner (semi rapid)

 

 

 

 

 

 

 

 

 

 

 

 

Heat Input

 

 

2.0 kW (6824 BTU/HR)

Rear Right Burner (semi rapid)

 

 

 

 

 

 

 

 

 

 

 

 

Heat Input

 

2.0 kW (6824 BTU/HR)

Front Left Burner (rapid)

 

 

 

 

 

 

 

 

 

 

 

 

Heat Input

3.0 kW Natural Gas (10236 BTU/HR)

Front Right Burner (auxiliary)

 

 

 

 

 

 

2.8 kW L.P.G. (9554 BTU/HR)

Heat Input

 

1.0 kW (3412 BTU/HR)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OFTYPE

GAS

 

CHARACTERISTICS

 

BURNER

 

 

RAPID

SEMI-RAPID

AUXILIARY

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(large)

(medium)

(small)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POSITION

 

 

MAX

MIN

MAX

 

MIN

MAX

MIN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NATURALGAS

20mbar

 

=VALUE37.78 MJ/m3 50.7-WsMJ/ m

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

POWER

kW

 

3.0

0.65

 

2.0

 

0.45

1.0

0.33

 

 

 

 

 

 

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATE

m3/h

 

0.286

0.057

 

0.190

 

0.038

0.095

0.028

 

 

 

 

 

 

 

 

NOZZLE REFERENCE

 

119

Adjust.

96

 

Adjust.

70

Adjust.

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GASLPG

mbar30/37-28

 

MJ/Kg49.92=VALUE

 

NOMINAL THERMAL

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER

kW

 

2.8

0.65

 

2.0

 

0.45

1.0

0.33

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOMINAL FLOW

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATE

g/h

 

202

43.5

 

144

 

29

72

21,5

 

 

 

 

 

 

 

 

NOZZLE REFERENCE

 

86

40

 

71

 

32

50

28

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CLASS APPLIANCE: 3

Burner

 

Dia. Tap By-pass

 

Tap colour

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/100 mm

 

 

 

 

 

APPLIANCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auxiliary

 

28

 

Yellow/Red

 

CATEGORY: II2H3+

Semi-rapid

 

32

 

Green/Black

 

APPLIANCE

 

 

 

Rapid

 

40

 

Violet/Black

 

 

 

 

 

 

 

GAS SUPPLY: Natural gas G20 / 20mbar

Aeration adjustment none

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12

Image 11
Contents Instruction Booklet During Use Important Safety InformationChild Safety ServiceContents EHG Hob Top InstallationWhen the HOB is First Installed Description of the HobDiameter OperationHOB Burners Burner Minimum MaximumBurners Maintenance and CleaningHobTop Pan SupportsCustomer Care Service and Spare PartsSymptom Solution Something Not Working?European Guarantee Guarantee ConditionsElectrolux Standard Guarantee Conditions Exclusions This guarantee does not coverWales Channel IslandsScotland Northern IrelandSouth West MidlandsLondon & East Anglia South EastCUT OUT Dimensions Instructions for the InstallerEngineer technical data Overall DimensionsLocation Important safety requirementsRectangular cut-out size for hob InstallationGas Connection Cut Out SizeFitting the hob to the worktop BuildingBuilding over a kitchen unit with door This HOB Must be Earthed Electrical connectionsIgnitor Switch Ignitor Unit Wiring diagramEarth Continuity Check Fault FindingPreliminary Electrical Systems Check Ignition System / Gas Ignition Commissioning ProcedurePressure Testing Servicing To Adjust the GAS Rate