OVERALL DIMENSIONS

Width:

590 mm

 

Depth:

520 mm

CUT OUT DIMENSIONS

Width:

560 mm

 

Depth:

480 mm

SUPPLY CONNECTIONS

Gas:

R 1/2 inch (1/2 inch male) Rear right hand corner

Electric:

230 V~ 50 Hz supply, 3 core flexible cable with non rewireable plug fitted with a 3 amp cartridge fuse.

HEAT INPUT

 

 

Rear Right Burner

1.9 kW (6485 BTU/HR)

(semi-rapid)

 

 

Front Right Burner

1.9 kW (6485 BTU/HR)

(semi-rapid)

 

 

Rear Left Burner

2.9 kW Natural Gas (9898 BTU/HR)

(rapid)

2.7 kW L.P.G.

Front Left Burner

1.0 kW (3413 BTU/HR)

(auxiliary)

 

 

APPLIANCE CLASS

3

 

APPLIANCE CATEGORY

GB - IE: II2H3+

GAS SUPPLY

 

Natural gas G20 (2H) 20 mbar

This appliance is manufactured according to the following EEC directives:

2006/95 EEC - 2004/108 EEC - 2009/142 EEC, current edition.

Image 13
Contents GB IE Page Welcome to the world of Electrolux Contents Installation Important Safety InformationPeople Safety During UseEnvironmental Information ServiceInstructions for the User Description of the HobHob burners control knobs OperationLighting the burners Burner Minimum Maximum Diameter Using the hob correctlyHob Top Maintenance and CleaningPan Supports Periodic MaintenanceBurners Ignition electrodeSomething Not Working? Symptom SolutionEngineer technical data Instructions for the InstallerCharacteristics of gas burners Provision for Ventilation Important safety requirementsInstallation Gas Connection Place the hob in the cut out, taking care of its centring Fitting the Hob into the WorktopBuilding over a cupboard or drawer BuildingBuilding over a kitchen unit with door This HOB Must be Earthed Electrical ConnectionsPermanent Connection Procedure Pressure TestingCommissioning Method Conversion from Natural Gas to LPG08445 616 Standard Guarantee ConditionsTel 08445 613 European Guarantee Electrolux 39714-4201