Permanent Connection

In the case of a permanent connection, it is necessary that you install a double pole switch between the hob and the electricity supply (mains), with a minimum gap of 3 mm between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations.

The switch must not break the yellow and green earth cable at any point.

Ensure that the hob supply cord does not come into contact with surfaces with temperatures higher than 90 deg. C.

Supply cable replacement

The cable used to connect the hob to the electrical supply must comply to the specifications given below.

Min. size

 

 

Cable/flex

Cable / flex type

Fuse

0.75 mm2

H05 V2V2-F (T90)

3 A

 

 

 

Image 21
Contents GB IE Page Welcome to the world of Electrolux Contents Installation Important Safety InformationPeople Safety During UseEnvironmental Information ServiceInstructions for the User Description of the HobOperation Hob burners control knobsLighting the burners Burner Minimum Maximum Diameter Using the hob correctlyHob Top Maintenance and CleaningPan Supports Periodic MaintenanceBurners Ignition electrodeSomething Not Working? Symptom SolutionEngineer technical data Instructions for the InstallerCharacteristics of gas burners Provision for Ventilation Important safety requirementsInstallation Gas Connection Place the hob in the cut out, taking care of its centring Fitting the Hob into the WorktopBuilding Building over a cupboard or drawerBuilding over a kitchen unit with door This HOB Must be Earthed Electrical ConnectionsPermanent Connection Pressure Testing ProcedureCommissioning Method Conversion from Natural Gas to LPG08445 616 Standard Guarantee ConditionsTel 08445 613 European Guarantee Electrolux 39714-4201