Electrolux EHT 60410 manual Conversion from Natural Gas to LPG, Method

Page 23

electrolux 23

Conversion from Natural Gas to LPG

IMPORTANT

The replacement/conversion from natural gas to LPG should only be undertaken by a competent person.

It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted. The gas rate is adjusted to suit.

Method

)1) Ensure that the gas taps are in the 'OFF' position

2)Isolate the hob from the electricity supply

3)Remove all pan supports, burner caps, rings, crowns and control knobs.

4)With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injectors.

TO ADJUST THE GAS RATE

With the aid of a thin bladed screwdriver completely tighten down the by pass adjustment screw. Upon completion stick the replacement rating plate on the under side of the hob.

Image 23
Contents GB IE Page Welcome to the world of Electrolux Contents During Use Important Safety InformationInstallation People SafetyEnvironmental Information ServiceInstructions for the User Description of the HobLighting the burners OperationHob burners control knobs Burner Minimum Maximum Diameter Using the hob correctlyHob Top Maintenance and CleaningIgnition electrode Periodic MaintenancePan Supports BurnersSomething Not Working? Symptom SolutionEngineer technical data Instructions for the InstallerCharacteristics of gas burners Provision for Ventilation Important safety requirementsInstallation Gas Connection Place the hob in the cut out, taking care of its centring Fitting the Hob into the WorktopBuilding over a kitchen unit with door BuildingBuilding over a cupboard or drawer This HOB Must be Earthed Electrical ConnectionsPermanent Connection Commissioning Pressure TestingProcedure Method Conversion from Natural Gas to LPG08445 616 Standard Guarantee ConditionsTel 08445 613 European Guarantee Electrolux 39714-4201