A. EARTH CONTINUITY CHECK

Appliance must be electrically disconnected - meter set on W (Ohms) x 1 scale and adjust zero if necessary.

Test leads from any appliance earth point to earth pin on plug. Resistance should be less than 0.1 W (Ohm), check all earth wires for continuity and all contacts clean and tight.

B.INSULATION CHECK

Appliance electrically disconnected, all switches ON.

a)meter set on W (Ohms) x 1 scale.

Test leads from L to N in appliance terminal block. If meter reads «0» then there is a short circuit.

b)meter set on W (Ohm) x 100 scale.

Repeat test with leads from L to E. If meter reads less than × (infinity) there is a fault.

NOTE - Should it be found that the fuse has failed but no fault is indicated

-a detailed continuity check (i.e. by disconnecting and checking each component) is required to trace the faulty component.

It is possible that a fault could occur as a result of local burning/arcing but no fault could be found under test. However a detailed visual inspection should reveal evidence of burning around the fault.

Image 27
Contents Instruction booklet Electrolux Welcome to the world of Electrolux Contents During Use Important safety informationInstallation Child SafetyService ∀ Environmental Information Description of the hob Installation Triple crown burner OperationHob burners control knobs Lighting the burnersBurner Minimum Maximum Diameter Using the hob correctlyMaintenance and Cleaning Hob TopPan Supports Ignition electrode BurnersSomething not working? SymptomEngineer technical data Instructions for the InstallerType of GAS Location Important safety requirementsInstallation Gas Connection Cut out size Building Building over a cupboard or drawerBuilding over a kitchen unit with door Carry out the building in of the hob as follows Fitting the hob into the worktopThis HOB Must be Earthed Electrical connections Permanent Connection Wiring diagram Preliminary Electrical Systems Check Fault findingEarth Continuity Check Ignition System / Gas Ignition Commissioning Pressure TestingProcedure Minimum adjustmentMethod Conversion from natural gas to LPGExclusions Standard guarantee conditions0870 5 929 Service and Spare PartsEuropean guarantee Electrolux Electrolux 35693-2601 03/07 R.0