Electrolux EHG 9832 manual Ignition System / Gas Ignition

Page 28

28electrolux

Ignition System / Gas Ignition

Ignitor does not spark

NO

Check plug top fuse and replace if necessary

Check polarity and earth continuity of supply point

Check earth continuity of appliance

YES

Check gas supply at burner

Light burner manually

Check by pass simmer adjusted

Check position of the electrode

Check fitting of burners

Check continuity from 'N' on the mains connector block and "O" on the ignitor unit

Check continuity from 'L' on the mains connector block and the taps ignition switches

Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit

Check for breaks in the insulation of the HT leads

Check continuity from ignition switches connector to ignitor unit

Change the ignitor unit

Image 28
Contents Instruction booklet Electrolux Welcome to the world of Electrolux Contents Important safety information InstallationChild Safety During UseService ∀ Environmental Information Description of the hob Installation Operation Hob burners control knobsLighting the burners Triple crown burnerUsing the hob correctly Burner Minimum Maximum DiameterHob Top Maintenance and CleaningPan Supports Burners Ignition electrodeSymptom Something not working?Instructions for the Installer Engineer technical dataType of GAS Important safety requirements LocationInstallation Gas Connection Cut out size Building over a cupboard or drawer BuildingBuilding over a kitchen unit with door Fitting the hob into the worktop Carry out the building in of the hob as followsElectrical connections This HOB Must be EarthedPermanent Connection Wiring diagram Fault finding Preliminary Electrical Systems CheckEarth Continuity Check Ignition System / Gas Ignition Pressure Testing ProcedureMinimum adjustment CommissioningConversion from natural gas to LPG MethodStandard guarantee conditions ExclusionsService and Spare Parts 0870 5 929European guarantee Electrolux Electrolux 35693-2601 03/07 R.0