10electrolux
Operation
Hob burners control knobs
The symbols on the knobs mean that :
#there is no gas supply
there is maximum gas supply
there is minimum gas supply
Lighting the burners
For easier lighting, proceed before putting a pan on the pan support.
!To light a burner:
# push in the relevant control knob and turn
it anticlockwise to maximum position (), to ignite the burner.
# After lighting the flame, keep the knob pushed down for about 5 seconds. This will allow the "thermocouple" (Fig. 1 - lett. D) to be heated and the safety device to be switched off, otherwise the gas supply would be interrupted.
# Then adjust the flame as required.
If the burner does not ignite, turn the control knob to zero, and try again.
When switching on the mains, after installation or a power cut, it is quite normal for the spark generator to be activated automatically.
In the absence of electricity, ignition can occur without the electrical device; in this case, approach the burner with a flame, push the relevant knob down and turn it
Triple crown burner | |
| A |
| B |
| D |
C |
|
A - Burner cap | Fig. 1 |
B - Burner crown |
|
C - Ignition electrode | |
D- Thermocouple |
|
ACappellotto