Diagnostic error codes

Note: In the following error codes, if XXX is 000, 195, or 197do not replace a FRU. The description for these error codes are:

000The test passed.

195The Esc key was pressed to abort the test.

197This is a warning error and may not indicate a hardware failure. For all error codes, replace/follow the FRU/Action indicated.

Error Code/Symptom

 

FRU/Action

 

 

 

 

001-XXX-000

(Failed

1.

System Board

core tests)

 

 

 

 

 

 

 

001-XXX-001

(Failed core

1.

System Board

tests)

 

 

 

 

 

 

 

001-250-000

(Failed

1.

System Board

System Board ECC)

 

 

 

 

 

 

001-250-001

(Failed

1.

System Board

System Board ECC)

 

 

 

 

 

 

005-XXX-000

(Failed

1.

Video Adapter (if installed)

Video test)

 

2.

System Board

 

 

 

 

 

 

011-XXX-000

(Failed

1.

System Board

COM1 Serial Port test)

 

 

 

 

 

 

011-XXX-001

 

1.

System Board

(Failed COM2 Serial Port test)

 

 

 

 

 

 

014-XXX-000

 

1.

System Board

(Failed Parallel Port test)

 

 

 

 

 

 

015-XXX-001

 

1.

System Board

(USB interface not found,

 

 

board damaged)

 

 

 

 

 

 

 

015-XXX-015

 

1.

Make sure parallel port is not disabled

(Failed USB External

2.

Re-run USB External Loopback test

Loopback test)

 

 

3.

System Board

 

 

 

 

 

 

015-XXX-198

 

1.

Remove USB devices from USB1 and USB2

(USB device connected

2.

Re-run test

during USB test)

 

 

3.

System Board

 

 

 

 

 

 

020-XXX-000

(Failed

1.

System Board

PCI Interface test)

 

 

 

 

 

 

030-XXX-000

(Failed

1.

System Board

Internal SCSI interface test)

 

 

 

 

 

 

030-XXX-00N

(Failed

1.

Adapter in Slot N

SCSI test on PCI slot N.

 

 

Check system error log before

 

 

replacing a FRU.)

 

 

 

 

 

 

 

035-XXX-099

 

1.

No adapters were found.

 

 

2.

If adapter is installed re-check connection.

 

 

 

 

Symptom-to-FRU index 115