Error Code/Symptom |
|
|
|
| FRU/Action | ||
|
|
|
|
|
|
| |
01298200 |
|
|
| 1. | Ensure all microprocessors are the same speed. | ||
(Microprocessor speed |
|
|
|
|
| ||
mismatch) |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
I9990301 | (Fixed boot |
| 1. | Hard Disk Drive | |||
sector error) |
|
|
| 2. | If RAID system, refer to the Hardware Maintenance Manual for the specific RAID | ||
|
|
|
| ||||
|
|
|
|
| adapter. |
| |
|
|
|
| 3. | SCSI Backplane | ||
|
|
|
| 4. | Cable |
| |
|
|
|
| 5. | System Board | ||
|
|
|
|
|
|
| |
I9990305 | (Fixed boot |
| 1. | Install operating system to hard disk drive. | |||
sector error, no operating |
|
|
|
|
| ||
system installed) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
I9990650 | (AC |
| 1. | Check cable |
| ||
power has been restored) |
| 2. | Check for interruption of power supply | ||||
|
|
|
| ||||
|
|
|
| 3. | Power Cable |
| |
|
|
|
|
|
| ||
Other numbers |
|
|
| Follow instructions on screen. | |||
|
|
|
|
| |||
|
|
|
|
|
|
|
|
Processor board LEDs |
| ||||||
| Table 18. . |
|
|
| |||
|
|
|
|
|
|
| |
|
|
|
| LED |
| Cause | |
|
|
|
|
|
|
| |
|
| Fan |
|
| 1. | Replace the fan assembly indicated by lit LED. | |
|
|
|
|
|
| ||
|
| Memory |
| 1. | Replace the DIMM indicated by the lit DIMM error. | ||
|
|
|
|
|
|
| |
|
| CPU |
|
| 1. | Turn off the server, reseat the microprocessor, and restart the server. | |
|
|
|
|
|
| 2. | Replace the microprocessor. |
|
|
|
|
|
|
| |
|
| VRM |
|
| 1. | Turn off the server, reseat the VRM indicated by the lit VRM error | |
|
|
|
|
|
|
| LED, and restart the server. |
|
|
|
|
|
| 2. | Replace the VRM |
|
|
|
|
|
|
|
|
ServeRAID
For ServeRAID error codes and procedures, refer to the Hardware Maintenance
Manual for the particular RAID adapter in the system being serviced.
Undetermined problems
You are here because the diagnostic tests did not identify the failure, the Devices List is incorrect, or the system is inoperative.
Note: A corrupt CMOS can cause undetermined problems.
If power problems are suspected:
1.
2.Be sure the system is cabled correctly.