Error Code/Symptom

 

 

 

 

FRU/Action

 

 

 

 

 

 

 

01298200

 

 

 

1.

Ensure all microprocessors are the same speed.

(Microprocessor speed

 

 

 

 

 

mismatch)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I9990301

(Fixed boot

 

1.

Hard Disk Drive

sector error)

 

 

 

2.

If RAID system, refer to the Hardware Maintenance Manual for the specific RAID

 

 

 

 

 

 

 

 

 

adapter.

 

 

 

 

 

3.

SCSI Backplane

 

 

 

 

4.

Cable

 

 

 

 

 

5.

System Board

 

 

 

 

 

 

 

I9990305

(Fixed boot

 

1.

Install operating system to hard disk drive.

sector error, no operating

 

 

 

 

 

system installed)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

I9990650

(AC

 

1.

Check cable

 

power has been restored)

 

2.

Check for interruption of power supply

 

 

 

 

 

 

 

 

3.

Power Cable

 

 

 

 

 

 

 

Other numbers

 

 

 

Follow instructions on screen.

 

 

 

 

 

 

 

 

 

 

 

 

 

Processor board LEDs

 

 

Table 18. .

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LED

 

Cause

 

 

 

 

 

 

 

 

 

Fan

 

 

1.

Replace the fan assembly indicated by lit LED.

 

 

 

 

 

 

 

 

Memory

 

1.

Replace the DIMM indicated by the lit DIMM error.

 

 

 

 

 

 

 

 

 

CPU

 

 

1.

Turn off the server, reseat the microprocessor, and restart the server.

 

 

 

 

 

 

2.

Replace the microprocessor.

 

 

 

 

 

 

 

 

 

VRM

 

 

1.

Turn off the server, reseat the VRM indicated by the lit VRM error

 

 

 

 

 

 

 

LED, and restart the server.

 

 

 

 

 

 

2.

Replace the VRM

 

 

 

 

 

 

 

 

ServeRAID

For ServeRAID error codes and procedures, refer to the Hardware Maintenance

Manual for the particular RAID adapter in the system being serviced.

Undetermined problems

You are here because the diagnostic tests did not identify the failure, the Devices List is incorrect, or the system is inoperative.

Note: A corrupt CMOS can cause undetermined problems.

If power problems are suspected:

1.Power-off the computer.

2.Be sure the system is cabled correctly.

124Hardware Maintenance Manual: xSeries 220