3.Remove or disconnect the following (one at a time) until you find the failure (power-on the computer and reconfigure each time).

Any external devices

Surge suppressor device (on the computer)

Modem, printer, mouse, or non-IBM devices

Each adapter

Drives

Memory Modules (Minimum requirement = one 128 MB DIMM)

Note: Minimum operating requirements are:

a.1 Power Supply

b.System Board

c.1 Microprocessor

d.1 Terminator Card in Slot 2

e.1 Memory Module (minimum of 1 DIMM in slot labeled DIMM 1)

4.Power-on the computer. If the problem remains, suspect the following FRUs in the order listed:

Power Supply

System Board

Notes:

1.If the problem goes away when you remove an adapter from the system, and replacing that adapter does not correct the problem, suspect the system board, then the power supply.

2.If you suspect a networking problem and all the system tests pass, suspect a network cabling problem external to the system.

Symptom-to-FRU index 125