Temperature checkout

Proper cooling of the system is important for proper operation and system reliability. For a typical IBM xSeries server, you should make sure:

Each of the drive bays has either a drive or a filler panel installed

The cover is in place during normal operation

There is at least 50 mm (2 inches) of ventilated space at the sides of the server and 100 mm (4 inches) at the rear of the server

The cover is removed for no longer than 30 minutes while the server is operating

A removed hot-swap drive is replaced within two minutes of removal

Cables for optional adapters are routed according to the instructions provided with the adapters (ensure that cables are not restricting air flow)

The fans are operating correctly and the air flow is good

A failed fan is replaced within 48 hours

In addition, ensure that the environmental specifications for the system are met. See “Features and specifications” on page 4.