Beep/Symptom

 

FRU/Action

 

 

 

2-3-2

1.

System board

(Screen memory failed)

 

 

 

 

 

2-3-3

1.

System board

(Screen retrace failed)

 

 

 

 

 

2-3-4

1.

System board

(Search for video ROM

 

 

failed)

 

 

 

 

 

2-4-1

1.

System board

(Video failed, screen

 

 

believed operable)

 

 

 

 

 

3-1-1

1.

System Board

(Timer tick interrupt

 

 

failed)

 

 

 

 

 

3-1-2

1.

System Board

(Interval timer channel

 

 

2 failed)

 

 

 

 

 

3-1-3

1.

DIMM

(RAM test failed above

2.

Memory card

address OFFFFH)

3.

System board

 

 

 

 

3-1-4

1.

Battery

(Time-of-Day clock

2.

System Board

failed)

 

 

 

 

 

3-2-1

1.

System board

(Serial port failed)

 

 

 

 

 

3-2-2

1.

System board

(Parallel port failed)

 

 

 

 

 

3-2-3

1.

Optional processor (if installed)

(Math coprocessor

2.

Processor

failed)

3.

System board

 

 

 

 

3-2-4

1.

DIMM

(Failure comparing

2.

Battery

CMOS memory size

3.

System board

against actual)

 

 

 

3-3-1

1.

DIMM

(Memory size

2.

System board

mismatch occurred, see

"Memory Settings" on

3.

Battery

page 32)

 

 

 

 

 

3-3-2

1.

Disconnect the server power cord from outlet, wait 30 seconds and retry.

(Critical SMBUS error

2.

Unplug power, check for broken pins, and retry after reseating I2C cables between:

occurred) (I2C bus

 

a. system management adapter (PCI slot 2/J31) and planar (J32);

error)

 

 

 

b. DASD I2C on planar (J43) and DASD backplane

 

3.

System Board

 

4.

DIMMs

 

5.

Power Supply

 

6.

I2C Cable

 

 

 

Symptom-to-FRU index 113

Page 119
Image 119
IBM XSERIES 220 manual Optional processor if installed