Error Code/Symptom

 

FRU/Action

 

 

 

 

035-XXX-S99

(Failed

1.

Adapter

RAID test on PCI slot S. S =

2.

SCSI Backplane

number of failing PCI slot.

3.

Cable

Check System Error Log

before replacing a FRU.)

 

 

 

 

 

035-XXX-SNN (Check

1.

Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.

System Error Log before

 

 

replacing a FRU.

S =

 

 

number of failing PCI slot;

 

 

NN = SCSI ID of failing fixed

 

 

disk.)

 

 

 

 

 

 

 

035-253-S99

(RAID

1.

ServeRAID Adapter in slot S is not configured properly. Obtain the basic and

adapter initialization failure)

 

extended configuration status and refer to the ServeRAID Hardware Maintenance

 

 

 

Manual for more information.

 

 

2.

Cable

 

 

3.

Adapter

 

 

 

 

075-XXX-000

(Failed

1.

Power Supply

Power Supply test)

 

 

 

 

 

 

089-XXX-001

(Failed

1.

Microprocessor

Microprocessor test)

 

 

 

 

 

 

089-XXX-002

 

1.

Optional Microprocessor 2

(Failed Optional

 

 

 

Microprocessor test)

 

 

 

 

 

 

180-XXX-003

(Failed

1.

System Board

System Board LED test)

 

 

 

 

 

 

201-XXX-0NN

(Failed

1.

DIMM Location J1-J4

Memory test, see "Memory

2.

Memory card

Settings" on page 32.) NN =

 

 

DIMM location.

 

 

 

 

 

 

201-XXX-999 (Multiple

1.

See error text for failing DIMMs

DIMM failure, see error text.)

 

 

 

 

 

 

202-XXX-001

(Failed

1.

Microprocessor CPU 1

System Cache test)

 

 

 

 

 

 

202-XXX-002

(Failed

1.

Microprocessor CPU 2

System Cache test)

 

 

 

 

 

 

206-XXX-000

(Failed

1.

Cable

Diskette Drive test)

2.

Diskette Drive

 

 

 

 

3.

System Board

 

 

 

 

215-XXX-000

(Failed

1.

CD-ROM Drive Cables

IDE CD-ROM test)

2. CD-ROM Drive

 

 

 

 

3.

System Board

 

 

 

 

217-XXX-000

(Failed

1.

Fixed Disk 1

BIOS Fixed Disk test)

 

 

Note: If RAID is

 

 

configured, the fixed

 

 

disk number refers to

 

 

the RAID logical

 

 

array.

 

 

 

 

 

 

 

116Hardware Maintenance Manual: xSeries 220

Page 122
Image 122
IBM XSERIES 220 Error Code/Symptom FRU/Action XXX-S99, Adapter, 035-253-S99, Power Supply, Microprocessor, XXX-003, Cable