Quadra-Fire MTVERNON-AE-MBK Mt. Vernon Pellet Stove AE, Error Message, TC = Thermocouple

Models: MTVERNON-AE-MBK MTVERNON-AE-CSB MTVERNON-AE-CWL MTVERNON-AE-PMH

1 52
Download 52 pages 26.7 Kb
Page 29
Image 29
Error Message

R

 

 

 

 

 

 

 

 

 

Mt. Vernon Pellet Stove (AE)

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

With proper installation, operation, and maintenance your appliance will provide years of

 

 

 

 

 

trouble-free service. If you do experience a problem, this troubleshooting guide will assist

 

 

Troubleshooting a qualified service person in the diagnosis of a problem and the corrective action to be

 

 

 

 

 

taken. This troubleshooting guide can only be used by a qualified service technician.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Error Message

Possible Cause

Corrective Action

 

 

 

 

 

 

 

 

 

 

Bad wall control or control board

Replace wall control or control board

 

 

 

 

 

 

 

 

 

 

3 wires have loose connections or installed

Check connections

 

 

 

 

 

 

 

 

 

 

wrong

 

 

 

 

LOW BATTERY

Battery supply on battery backup is drained

Recharge battery

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAD TC DROP TUBE

Drop tube thermocouple is broken or leads are

Check connections

 

 

 

(TC = Thermocouple)

reversed

Replace thermocouple

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAD TC FIREPOT

Firepot thermocouple is broken or leads are

Check connections

 

 

 

(TC = Thermocouple)

reversed

Replace thermocouple

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SNAP DISC TRIPPED

Overheat sensor (snap disc) has tripped

Unplug the appliance and then manually

 

 

 

 

 

 

 

 

 

 

 

reset snap disc

 

 

 

VACUUM SW ERROR

Vacuum switch is bad

Check connections. Bypass vacuum

 

 

 

(SW = Switch)

 

with jumper wire, if runs, switch is bad.

 

 

 

 

Replace switch

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vacuum hose is plugged/disconnected

Check vacuum hose

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMB BLOWER JAMMED

Combustion blower is blocked/jammed

Remove blockage

 

 

 

 

 

 

 

 

 

 

 

Replace blower if necessary

 

 

 

 

 

 

 

 

 

 

 

Must uplug the appliance to clear the

 

 

 

 

 

 

 

 

 

 

 

error

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUGER JAMMED

Auger jammed, feed motor bad

Pull the feed system and inspect

 

 

 

 

 

 

 

 

 

 

 

Clear jam. Press Retry

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MISSED IGNITION

Igniter bad or poor harness connection

Check connections, if OK replace igniter

 

 

 

 

 

 

 

 

 

 

Out of fuel or fuel is bridging in hopper

Break up bridging pellets

 

 

 

 

 

 

 

 

 

 

Faulty firepot thermocouple connection has

Refill hopper

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

shorted.

Replace the thermocouple and then

 

 

 

 

 

 

 

 

 

 

 

press Retry

 

 

 

MIN FIREPOT TEMP

Out of fuel

Refill hopper

 

 

 

 

 

 

 

 

 

 

 

Add handful of pellets to firepot

 

 

 

 

 

 

 

 

 

 

 

Press Retry

 

 

 

MAX DROP TUBE TEMP

Wrong fuel table setting

Confim setting matches burning fuel

 

 

 

 

 

 

 

 

 

 

Flame height set too high

Adjust flame height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONV BLOWER JAMMED

Convection blower blocked/jammed

Remove blockage

 

 

 

 

 

 

 

 

 

 

 

Replace blower if necessary

 

 

 

 

 

 

 

 

 

 

 

Must uplug the appliance to clear the

 

 

 

 

 

 

 

 

 

 

 

error

 

 

 

CHECK ASHPAN

Auto-clean jammed

If ashpan is empty, check for a jam. Use

 

 

 

 

 

 

 

 

 

 

 

a screw driver and firmly push in the

 

 

 

 

 

 

 

 

 

 

 

firepot floor holes and flex spring and

 

 

 

 

 

 

 

 

 

 

 

push toward home to release jam.

 

 

 

 

 

 

 

 

 

 

Auto-clean switch is bad

Replace switch

 

 

 

 

 

 

 

 

 

 

Linkage has become disconnected

Reconnect linkage

 

 

 

 

 

 

 

 

 

 

Hopper lid open while you refill the hopper

Fill hopper between cycle

 

 

 

 

 

 

 

 

 

 

Switch is out of adjustment (auger will not

Adjust or replace switch

 

 

 

 

 

 

 

 

 

 

function)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SCREEN GOES BLANK

Static discharge or nearby lightening or

Unplug the power to the appliance and

 

 

 

 

 

 

 

 

 

 

Electric fast transients at the input mains

plug it back in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

September 1, 2008

7034-106E

Page 29

Page 29
Image 29
Quadra-Fire MTVERNON-AE-MBK, MTVERNON-AE-PMH Mt. Vernon Pellet Stove AE, Error Message, TC = Thermocouple, SW = Switch