A. Design, Installation & Location Considerations

1.Appliance Location

OT Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits.

It is a good idea to plan your installation on paper, using exact measurements for clearances and floor protection, before actually beginning the installation

Consideration must be given to:

Safety, convenience, traffic flow

Placement of the chimney and chimney connector.

If you are not using an existing chimney, place the appli- ance where there will be a clear passage for a factory- built listed chimney through the ceiling and roof.

Installing an optional outside air kit would affect the loca- tion of the vent termination.

Since pellet exhaust can contain ash, soot or sparks, you must consider the location of:

Windows

Air Intakes

Air Conditioner

Overhang, soffits, porch roofs, adjacent walls

Landscaping, vegetation

When locating vent and venting termination, vent above roof line when possible.

Damaged parts could impair safe operation. Do NOT install damaged, incomplete or substitute components.

T O If burning shelled field corn, you must use ap- proved venting specifically designed for corn to prevent corro- sion or degradation. Follow the instructions from the venting manufacturer.

OT Locating the appliance in a location of considerable air movement can cause intermittent smoke spillage from appliance. Do not locate appliance near:

Frequently open doors

Central heat outlets or returns

 

Recommended Location

Recommended Location

A ove pea

A ove pea

Inside heated space

Marginal Location Below pea

Marginal Location Wind loading possi le

Location NOT recommended Not the highest point of the roof Wind loading possi le

Windward

Recommended Outside Air Inta e on windward side

Recommended Insulated exterior chase in cooler climates

Multi-level Roofs

Location NOT recommended

Too close to tree

Below ad acent structure

Lower roof line

Avoid outside wall

Leeward

NOT recommended Outside Air Inta e on leeward side

Figure 5.1