Quadra-Fire MTVERNON-AE-MBK F. Wall Control Thermostat Installation, Mt. Vernon Pellet Stove AE

Models: MTVERNON-AE-MBK MTVERNON-AE-CSB MTVERNON-AE-CWL MTVERNON-AE-PMH

1 52
Download 52 pages 26.7 Kb
Page 21
Image 21
F. Wall Control Thermostat Installation

R

Mt. Vernon Pellet Stove (AE)

F. Wall Control Thermostat Installation

1.When mounting the wall control thermostat on the wall, be sure to follow your thermostat wall control’s instal- lation instructions carefully.

NOTE: The wall control thermostat should be mounted on an inside wall and not in direct line with the appliance convection air.

NOTE: If the wall control thermostat is located too close to the appliance, you may need to set the temperature setting slightly higher to maintain the desired temperature in your home.

2.There is a 5 screw terminal block located on the back lower left corner of the appliance directly above the power cord inlet.

The center 3 screws are for the wall control thermostat wires and the 2 outer screws are mounting screw and should not have wires attached to them.

The thermostat wires are color coded. The green wire is on the left, the white in the middle and the red on the right.

Figure 21.1 - Back Side of Wall Control with CAUTION

Shock hazard.

Do NOT remove grounding prong from plug.

Plug directly into properly grounded 3 prong receptacle.

Route cord away from appliance.

Do NOT route cord under or in front of appliance.

 

all Control

hermostat

ires

Atta h to Center

S re

s

 

 

 

 

 

 

 

 

 

 

 

 

 

reen

hite

Red

 

 

 

 

 

 

 

 

o shold Po er

 

volt Po er

nlet

for

Cord nlet

 

optional atter

a

k p

Figure 21.2

Top

Red Wire

Green Wire

White Wire

Bottom

Figure 21.1 - Back Side of Wall Control with

Cover Off

September 1, 2008

7034-106E

Page 21

Page 21
Image 21
Quadra-Fire MTVERNON-AE-MBK owner manual F. Wall Control Thermostat Installation, Mt. Vernon Pellet Stove AE, Cover Off