Quadra-Fire MTVERNON-AE-CSB, MTVERNON-AE-PMH owner manual Mt. Vernon Pellet Stove AE, Power Supply

Models: MTVERNON-AE-MBK MTVERNON-AE-CSB MTVERNON-AE-CWL MTVERNON-AE-PMH

1 52
Download 52 pages 26.7 Kb
Page 39
Image 39
17.Power Supply

R

Mt. Vernon Pellet Stove (AE)

17.Power Supply

The power supply is located at the rear of the appliance. It converts 120 volt AC current to 15 volt DC current to power the appliance.

18.Overheat Sensor (Snap Disc)

The overheat sensor is mounted on the back of the drop tube in the center of the appliance and has a reset button. To access it remove the right side panel. If the fire tries to burn back into the feed system or push exhaust up the feed tube, this sensor will shut the stove down, however the wall control will still display messages. This sensor must be manually re-set. Disconnect power before resetting.

19.Thermocouple - Firepot

This thermocouple is located on top of the firepot inside the thermocouple cover (ceramic protection tube). The thermocouple sends a millivolt signal to the control board telling the control board there is a fire in the firepot.

20.Thermocouple - Drop Tube

21.Vacuum Switch

The vacuum switch is located on the right side of the appliance under the feed motor behind right side panel and connects to the drop tube with a hose. This switch turns the feed system on when vacuum is present in the firebox. The vacuum switch is a safety device to shut off the feed motor if the exhaust or the heat exchanger system is dirty, plugged or if the firebox door is open.

22.Wall Control

The appliance is designed to run on a custom designed 3.3 volt DC thermostat wall control. It will not operate on any other wall control. Refer to the instructions supplied with the thermostat wall control.

23.Wiring Schematic for Control Board See Figure 39.1 below.

24.Wiring Schematic for Power Supply See Figure 39.2 below.

This thermocouple is located on the bottom of the drop tube on the right side and attached with a wing nut. It turns the convection blower on and off, varies the speed of the convection blower and will shut down appliance if internal heat exceeds set temperature.

13

12

11 n/a

10

9

8

7

6

5

 

 

 

 

 

 

 

 

4

Fuse 15A 120V,

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

under the cover

 

 

 

 

 

 

 

2

14

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

Fuse 15A 120V,

 

 

15

16

 

 

17

under the cover

 

 

 

 

 

 

Figure 39.1

Fuse 15A 250V

 

(need to remove

 

cover)

 

 

120V AC in

120V AC out to

15V DC out to

 

Control Board

Control Board

Figure 39.2

#Description

1Combustion Blower

2 Auto-Clean System

3 Feed/Auger Motors

4 Hopper/Door Switches

5Auger/Auto-Clean/Vacuum Switches

6Low Fuel

#Description

7Thermostat Wall Control

8Combustion Blower (feedback)

9 Firepot Thermocouple

10 Drop Tube Thermocouple n/a Not Used

11 Convection Blower (feedback)

#Description

12Igniter

13AC Power In for Igniter

14Convection Blower Power

15Overheat Sensor (Snap Disc)

16DC Power In from Power Supply

1712 Volt Battery Back-up

September 1, 2008

7034-106E

Page 39

Page 39
Image 39
Quadra-Fire MTVERNON-AE-CSB, MTVERNON-AE-PMH, MTVERNON-AE-MBK, MTVERNON-AE-CWL Mt. Vernon Pellet Stove AE, Power Supply