Quadra-Fire MTVERNON-AE-MBK Mt. Vernon Pellet Stove AE, f. Removing the Combustion Exhaust Blower

Models: MTVERNON-AE-MBK MTVERNON-AE-CSB MTVERNON-AE-CWL MTVERNON-AE-PMH

1 52
Download 52 pages 26.7 Kb
Page 33
Image 33
f. Removing the Combustion (Exhaust) Blower

R

Mt. Vernon Pellet Stove (AE)

f. Removing the Combustion (Exhaust) Blower

1.The combustion blower is mounted in the bottom right rear of the appliance. Figure 33.1.

2.Use an 11/32 nut driver to loosen all six nuts, but do not remove. Rotate the blower and remove from the housing. Figure 33.2.

3.Set the blower on the top of the housing. You do not need to disconnect the wires. Figure 33.3.

4.Vacuum out the exhaust area. Figure 33.4.

Set lo er on top of ho

sing

o not dis onne t the

ires

 

 

Figure 33.3

Va m o t the e ha st area

Combustion Blower

Figure 33.1

Figure 33.4

Loosen all n ts t do

Remove

 

 

Figure 33.2

September 1, 2008

7034-106E

Page 33

Page 33
Image 33
Quadra-Fire MTVERNON-AE-MBK, MTVERNON-AE-PMH Mt. Vernon Pellet Stove AE, f. Removing the Combustion Exhaust Blower