Quadra-Fire MTVERNON-AE-CSB C. Vertical into Existing Class A Chimney, Mt. Vernon Pellet Stove AE

Models: MTVERNON-AE-MBK MTVERNON-AE-CSB MTVERNON-AE-CWL MTVERNON-AE-PMH

1 52
Download 52 pages 26.7 Kb
Page 15
Image 15
C. Vertical into Existing Class A Chimney

R

Mt. Vernon Pellet Stove (AE)

C. Vertical into Existing Class A Chimney

Rain Cap

 

Flashing

 

12 in. (305mm) Minimum

 

Firestop

 

6 in. (152mm) Class A

 

Chimney Connector

 

Adapter

 

Ceiling Support

 

3 in. (76mm) Min.

6 in.

3 to 6 in. (76-152mm)

(152mm)

Offset Adapter

Min.

3 to 3 in.

 

 

(76-76mm)

 

Top Vent Kit

 

Clean-out Cover

Non-combustible Hearth Pad

Figure 15.1

We recommend a minimum of 60 inches (1524mm) vertical, however above the eave is preferred.

All three installations are approved for mobile home installations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Listed pellet venting or Listed double wall pipe and Quadra-Fire Out- side Air Kit in mobile homes. Single wall pipe is approved for residential installations only.

*NOTE: Clearance to combustibles are for standard pellet pipe. If pellet pipe manufac- turer allows reduced clearances to their pipe, reduced clearances are allowed.

D. Through The Wall & Vertical - Exterior

 

Rain

 

Cap

Flashing

12 in.

(305mm)

 

minimum

2 in. (51mm) minimum

Support

Bracket

 

 

every 60 in.

6 in. (152mm)

(1524mm)

 

minimum

Wall Thimble

 

 

Tee

 

Clean-out

 

Cover

Non-combustible Hearth Pad

Figure 15.2

E. Vertical - Interior - Typical Installation

Rain Cap

 

Flashing

12 in.

 

(305mm)

 

 

 

 

Minimum

 

Firestop

 

6 in.

 

3 in. (76mm)Min.

 

 

(152mm)

 

 

Min.

 

3 in. to 3 in.

 

 

(76-76mm)

 

 

Top Vent Kit

 

 

Clean-out Cover

Non-combustible Hearth Pad

Figure 15.3

September 1, 2008

7034-106E

Page 15

Page 15
Image 15
Quadra-Fire MTVERNON-AE-CSB C. Vertical into Existing Class A Chimney, D. Through The Wall & Vertical - Exterior