B. Clearances to Combustibles (UL and ULC)

R

Mt. Vernon Pellet Stove (AE)

B. Clearances to Combustibles (UL and ULC)

A

 

C

 

B

C

 

Straight Back Against Wall

Inches

Millimeters

 

A

Back Wall to Appliance

2

 

51

 

 

B

Side Wall to Appliance

6

 

152

 

 

 

 

 

 

 

 

 

 

Corner Installation

 

Inches

 

Millimeters

 

 

C

 

Walls to Appliance

 

2

 

51

 

Installations with:

3 to 3 inch Top Vent Adapter and

3 to 6 inch Offset Adapter Kit

F

 

D

G

 

 

 

 

G

E

C. Hearth Pad Requirements (UL and ULC)

Use a non-combustible floor protector, extending beneath appliance and to the front, sides and rear as indicated. Measure front distance “M” from the surface of the glass door.

L*

 

 

K

 

K

 

 

 

 

 

M

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hearth Pad Requirements

 

Inches

Millimeters

K

Sides

 

2

 

51

L*

Back

 

2

 

51

M

Front

 

6

 

152

*L Exception for Horizontal Installations:

USA INSTALLATIONS: A non-combustible floor protec- tion is recommended extending beneath the flue pipe when installed with horizontal venting or under the Top Vent Adapter with vertical installation.

CANADA INSTALLATIONS: A non-combustible floor protection extending beneath the flue pipe is required with horizontal venting or under the Top Vent Adapter with vertical installation.

Vertical Installation

Inches

Millimeters

D

Back Wall to Flue Pipe

3

76

E

Side Wall to Appliance

6

152

F

Back Wall to Appliance

8

203

 

 

 

Corner Installation

Inches

Millimeters

G

Side Wall to Flue Pipe

3

76

 

 

 

Alcove Installation

Inches

Millimeters

Minimum Alcove Height

43

1092

Minimum Alcove Side Wall

6

152

Minimum Alcove Width

40

1016

Maximum Alcove Depth

36

914

NOTE:

Illustrations reflect typical installations and are FOR DESIGN PURPOSES ONLY.

Illustrations/diagrams are not drawn to scale.

Actual installation may vary due to individual design preference.

Must extend 2 inches (51mm) beyond each

side of pipe (shaded area)

C. Hearth Pad Requirements (UL and ULC) WARNING

Fire Risk.

Comply with all minimum clearances to combustibles as specified.

Failure to comply may cause house fire.