Quadra-Fire MTVERNON-AE-PMH owner manual Listing and Code Approvals, A. Appliance Certification

Models: MTVERNON-AE-MBK MTVERNON-AE-CSB MTVERNON-AE-CWL MTVERNON-AE-PMH

1 52
Download 52 pages 26.7 Kb
Page 4
Image 4
1 Listing and Code Approvals

R

Mt. Vernon Pellet Stove (AE)

1 Listing and Code Approvals

A. Appliance Certification

Model

Mt. Vernon Pellet Stove AE

Laboratory

OMNI Test Laboratories, Inc.

Report No.

061-S-68-6

Type

Solid Fuel Room Heater/Pellet Type

Standard

ASTM E1509-04, ULC S627-00 and

 

ULC/ORD-C1482-M1990 Room Heater

 

Pellet Fuel Burning type and (UM) 84-

 

HUD, Mobile Home Approved.

FCC

Complies with Part 15 of FCC Rules.

 

Operation is subject to the following

 

two conditions: (1) this device may not

 

cause harmful interference, and (2) this

 

device must accept any interference

 

received, including interference that

 

may cause undesired operation.

E. BTU & Efficiency Specifications

Emissions Rating:

EPA Compliance

*BTU Output:

14,620 - 60,200

Efficiency:

81.4% - 83.6%

Heating Capacity:

2,400 - 3,800 square feet depend-

 

ing on heating zone

Hopper Capacity:

81 lbs

Fuels:

Pellets, Shelled Field Corn, Wheat

 

and Black Sunflower Seeds

Shipping Weight:

429 lbs

*BTU output will vary, depending on the type of fuel you use in your stove. Consult your Quadra-Fire dealer for best results.

B. Mobile Home Approved

This appliance is approved for mobile home installations when not installed in a sleeping room and when an outside combustion air inlet is provided. The structural integrity of the mobile home floor, ceiling, and walls must be maintained. The appliance must be properly grounded to the frame of the mobile home and use only listed pellet vent Class “L” or “PL” connector pipe. A Quadra-Fire Outside Air Kit must be installed in a mobile home installation.

NOTE: Hearth & Home Technologies, manufacturer of this appliance, reserves the right to alter its products, their specifications and/or price without notice.

C. Glass Specifications

This appliance is equipped with 5mm ceramic glass. Replace glass only with 5mm ceramic glass. Please contact your dealer for replacement glass.

NOTE: This installation must conform with local codes. In the absence of local codes you must comply with the

ASTM E1509, ULC S627-00, (UM) 84-HUD and ULC/ ORD-C-1482.

D. Electrical Rating

115 VAC, 60 Hz, Start 5 Amps, Run 1.25 Amps

Page 4

7034-106E

September 1, 2008

Page 4
Image 4
Quadra-Fire MTVERNON-AE-PMH Listing and Code Approvals, A. Appliance Certification, E. BTU & Efficiency Specifications