INSTALLATION
Installing Optional Glass Door Accessory (Cont.) Opening Vent Damper
17
INSTALLATION
Continued
5.Once the top and bottom pins are secured, unfold the door into the closed position.
6.Repeat the process for the opposite door assembly.
7.To adjust the doors, slide them partially open. Using a screw- driver, loosen the
8.Close both doors until evenly joined at the middle and note the gap at the outer edges of the face.
9.Reopen one door at a time and retighten the upper and lower
10.Repeat the process until both doors are evenly joined, spaced and working freely.
CAUTION: The glass panels become very hot while the appliance is operating. Do not attempt to adjust or clean the glass doors until the appliance has fully cooled.
The doors may be removed for replacement or cleaning as follows:
1.Partially open the door and press up on the upper spring clip with a screw driver until the outer top pivot pin is free of the clip.
2.Fully fold the frame assembly and slide the upper edge to- wards the center of the firebox opening until the guide pins are free of the frame rail (see Figure 37).
CAUTION: Always operate the appliance with the doors either fully opened or fully closed. Operating the appliance with the doors partially open can result in improper venting of flue products.
Spring Clip
| Spring Clip |
| Depress Spring |
| Clip to Release |
| Pivot Pin |
Fold |
|
Door After |
|
Releasing | Remove |
Spring Clip and | Bottom Pin |
Slide Door Out | From Pivot |
of Upper Track | Plate While |
| Sliding Door |
| Out of the |
| Upper Track |
| Pivot Plate |
Figure 37 - Removing Glass Doors |
|
OPENING VENT DAMPER
Vent damper must be locked in the full open position before operating the fireplace. If vent damper is not open, fireplace will not light.
| VENT DAMPER MUST BE LOCKED |
|
| IN THE FULL OPEN POSITION |
|
OPEN | TO OPERATE THE APPLIANCE | CLOSE |
|
Side Front Face
Partially
Opened
Door
Figure 38 - Opening Vent Damper
Figure 36 - Adjusting Glass Doors
For more information, visit www.desatech.com