TROUBLESHOOTING
21
TROUBLESHOOTING
Note: For additional help, visit DESA’s Technical Service web site at www.desatech.com.
Note: Before troubleshooting the system, make sure the gas shutoff valve is ON.
The two most common causes of a malfunctioning gas appliance are:
1.Loose wiring connections
2.Construction debris clogging the pilot and/or gas control valve filter
| OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
| Pilot will not light | 1. | No gas supply, or shutoff valve is OFF | 1. | Check to see if you have gas supply | 
| 
 | 2. | Air in gas line | 2. | Hold regulator control valve in the PILOT | 
| 
 | 
 | 
 | 
 | position for 2 to 3 minutes to purge air. If | 
| 
 | 
 | 
 | 
 | you smell gas stop and wait for a few min- | 
| 
 | 
 | 
 | 
 | utes before trying to light the fireplace | 
| 
 | 3. | Construction debris clogging pilot orifice | 3. | Remove debris and dirt, inspect and | 
| 
 | 
 | 
 | 
 | clean any other possible obstructions | 
| 
 | 4. | Low gas pressure | 4. | Contact your gas supplier | 
| 
 | 5. | Control valve knob is not on the PILOT | 5. | Refer to section on pilot lighting | 
| 
 | 
 | position | 
 | 
 | 
| 
 | 6. | Kinked pilot line | 6. | Have a qualified technician replace pi- | 
| 
 | 
 | 
 | 
 | lot line | 
| 
 | 7. | Bad valve | 7. | Replace regulator valve (see Accesso- | 
| 
 | 
 | 
 | 
 | ries, page 29) | 
| 
 | 8. | Vent damper not fully open | 8. | Open vent damper until fully locked in | 
| 
 | 
 | 
 | 
 | OPEN position | 
| 
 | 
 | 
 | 
 | 
 | 
| Pilot will not stay lit | 1. | Loose wiring on thermopile to regula- | 1. | Check wiring connections. Refer to wir- | 
| 
 | 
 | tor valve. No millivolt current is being | 
 | ing diagram shown in Wall Switch In- | 
| 
 | 
 | sent back to regulator | 
 | stallation, page 11 | 
| 
 | 2. | If valve knob and wall switch are in the | 2. | Have a qualified technician replace valve | 
| 
 | 
 | ON position, probable defective regula- | 
 | 
 | 
| 
 | 
 | tor valve | 
 | 
 | 
| 
 | 3. | Vent damper not fully open | 3. | Open vent damper until fully locked in | 
| 
 | 
 | 
 | 
 | OPEN position | 
| 
 | 
 | 
 | 
 | 
 | 
| No gas to burner, although wall switch and | 1. | Wall switch wires defective or too long | 1. | Check electrical connections | 
| valve are set to the ON position | 2. | Thermopile not generating sufficient | 2. | See Pilot will not stay lit, above | 
| 
 | 
 | voltage | 
 | 
 | 
| 
 | 
 | 
 | 
 | 
 | 
| Frequent pilot outage | 1. | Pilot flame may be too low, causing | 1. | Clean and adjust pilot flame for maximum | 
| 
 | 
 | safety pilot to “drop out” | 
 | flame impingement on thermopile | 
| 
 | 2. | Improper venting or excessive blockage | 2. | Have the vent system inspected, includ- | 
| 
 | 
 | 
 | 
 | ing the termination cap. Remove any | 
| 
 | 
 | 
 | 
 | restriction or obstruction | 